Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 Oct;171(4):884-92.
doi: 10.1016/s0002-9378(94)70055-9.

Rapid echocardiographic assessment of left and right heart hemodynamics in critically ill obstetric patients

Affiliations
Clinical Trial

Rapid echocardiographic assessment of left and right heart hemodynamics in critically ill obstetric patients

M A Belfort et al. Am J Obstet Gynecol. 1994 Oct.

Abstract

Objective: Our purpose was to compare noninvasive two-dimensional and Doppler echocardiography and right heart catheterization with a pulmonary artery catheter in the estimation of stroke volume, cardiac output, cardiac index, left ventricular filling pressure, pulmonary artery systolic pressure, and right atrial pressure in a heterogeneous group of critically ill obstetric patients.

Study design: Eleven critically ill obstetric patients requiring invasive monitoring for clinical management were prospectively studied. Simultaneous Doppler and pulmonary artery catheter readings of stroke volume, cardiac output, cardiac index, left ventricular filling pressure, pulmonary artery systolic pressure, and right atrial pressure were acquired. Mean +/- SD or median and range, as appropriate, of each parameter were compared, and data for all parameters were subjected to regression analysis. A two-tailed p value < 0.05 was regarded as significant.

Results: There was no significant difference between the two techniques in the estimation of cardiac index, intracardiac pressures, or pulmonary artery systolic pressure. There was a good correlation between the two methods for stroke volume (R2 = 0.98), cardiac output (R2 = 0.98), cardiac index (R2 = 0.96), left ventricular filling pressure (R2 = 0.79), pulmonary artery systolic pressure (R2 = 0.85), and right atrial pressure (R2 = 0.86).

Conclusion: Two-dimensional and Doppler echocardiography allow rapid, reliable, noninvasive assessment of hemodynamic parameters in critically ill obstetric patients and may give the clinician valuable information that may influence therapeutic and clinical management.

PubMed Disclaimer

Publication types

MeSH terms