Clinical results with three different kinds of small optic PMMA-IOLs
- PMID: 7960417
- DOI: 10.1007/BF00919407
Clinical results with three different kinds of small optic PMMA-IOLs
Abstract
In this prospective study the clinical results using three different small optic IOLs are presented. The best results were achieved in those cases with an anterior capsule rim overlapping the entire optic periphery. In those cases with sulcus fixation, haptic in/out and optic in/out positions a higher percentage of capsule fibrosis (Soemmering's rings) was documented (sulcus fixation: 100%, haptic in/out position: 75%, optic in/out position: 65.5%, bag: 7.3%). The fibrosis developed because of contact between the anterior and the posterior capsule leaf. These cases also showed decentrations of the intraocular lens (IOL) more often (sulcus fixation: 50%, haptic in/out position: 75%, optic in/out position: 34.5%, bag: 31.7%). Only one patient was disturbed by glare and halo phenomenons. Cellular reactions on the lens surface were moderate in most cases. Differences specific to lens type were found between the three IOLs implanted. The clinical results were comparable to the results of other comprehensive IOL studies. Under certain indication small optic IOLs represent an alternative to flexible implants for small incision surgery.
Similar articles
-
Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification.Ophthalmology. 1999 May;106(5):891-900. doi: 10.1016/S0161-6420(99)00506-0. Ophthalmology. 1999. PMID: 10328386
-
Experimental study of different intraocular lens designs implanted in the bag after capsulorhexis.J Cataract Refract Surg. 1996 Nov;22(9):1211-21. doi: 10.1016/s0886-3350(96)80070-8. J Cataract Refract Surg. 1996. PMID: 8972372
-
Evaluation of a one-piece poly(methyl methacrylate) intraocular lens with a 7 mm biconvex optic and a total diameter of 10 mm.J Cataract Refract Surg. 1993 Jan;19(1):16-21. doi: 10.1016/s0886-3350(13)80273-8. J Cataract Refract Surg. 1993. PMID: 8426314
-
Complications of cataract and refractive surgery: a clinicopathological documentation.Trans Am Ophthalmol Soc. 2001;99:95-107; discussion 107-9. Trans Am Ophthalmol Soc. 2001. PMID: 11797325 Free PMC article. Review.
-
Intraocular lenses.Curr Opin Ophthalmol. 1990 Feb;1(1):42-8. doi: 10.1097/00055735-199002000-00010. Curr Opin Ophthalmol. 1990. PMID: 10149666 Review. No abstract available.
Cited by
-
Surface chemistry influences implant biocompatibility.Curr Top Med Chem. 2008;8(4):270-80. doi: 10.2174/156802608783790901. Curr Top Med Chem. 2008. PMID: 18393890 Free PMC article. Review.
-
Surface chemistry influences implant-mediated host tissue responses.J Biomed Mater Res A. 2008 Sep;86(3):617-26. doi: 10.1002/jbm.a.31649. J Biomed Mater Res A. 2008. PMID: 18022841 Free PMC article.