Quantitative mapping of regional cerebral blood flow using iodine-123-IMP and SPECT
- PMID: 7989987
Quantitative mapping of regional cerebral blood flow using iodine-123-IMP and SPECT
Abstract
A method was developed to calculate functional images of regional cerebral blood flow (rCBF) from a single scan using SPECT following intravenous 123I-N-isopropyl-p-iodoamphetamine (IMP) infusion.
Methods: A two-compartment model that includes two parameters of rCBF and regional distribution volume of IMP (Vd) was employed to correct for clearance of IMP from the brain. Using a given input function and a fixed Vd value (30 ml/ml according to an analysis on dynamic SPECT data), a unique value of rCBF was calculated for each pixel of the SPECT image according to the table-look-up procedure. This technique was applied to 15 human subjects, and the calculated rCBF values were compared with those measured by PET.
Results: A set of simulation studies demonstrated an optimal SPECT midscan time at 30 to 40 min postinjection of IMP, providing the minimal error sensitivity to the individual difference of the input function (rCBF values with an accuracy of +/- 10%). Another set of simulation suggested validity of fixing the Vd values, i.e., errors in calculated rCBF values were around +/- 7% for a change of Vd of +/- 10%. The measured rCBF values obtained from 15 human subjects were independent on the SPECT scan time. The calculated rCBF values also agreed well with those obtained by the nonlinear least-squares fitting analysis that were obtained from the dynamic SPECT scan and the frequent arterial blood sampling and measurement of lipophilic fraction for each sample (0.54 + 0.88x, r = 0.86), suggesting the validity of the simplified procedures in this method.
Conclusion: These observations suggested the validity of this method as a clinical tool for quantitative measurement of rCBF.
Similar articles
-
[Quantitation of regional cerebral blood flow using 123I-IMP from a single SPECT scan and a single blood sampling--analysis on statistical error source and optimal scan time].Kaku Igaku. 1995 Mar;32(3):263-70. Kaku Igaku. 1995. PMID: 7739156 Japanese.
-
Validation of the dual-table autoradiographic method to quantify two sequential rCBFs in a single SPET session with N-isopropyl-[123I] p-iodoamphetamine.Eur J Nucl Med Mol Imaging. 2003 Jul;30(7):943-50. doi: 10.1007/s00259-003-1180-7. Epub 2003 May 7. Eur J Nucl Med Mol Imaging. 2003. PMID: 12734690 Clinical Trial.
-
A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling.Eur J Nucl Med. 1994 Oct;21(10):1072-84. doi: 10.1007/BF00181062. Eur J Nucl Med. 1994. PMID: 7828617
-
[Abnormally distributed regional cerebral blood flow in brain malformations detected by single photon emission computed tomography].Rinsho Shinkeigaku. 1997 Feb;37(2):99-105. Rinsho Shinkeigaku. 1997. PMID: 9164139 Review. Japanese.
-
[The contribution of single-photon emission-computed tomography in cerebral function diagnosis].Schweiz Med Wochenschr. 1990 Dec 1;120(48):1791-800. Schweiz Med Wochenschr. 1990. PMID: 2084833 Review. German.
Cited by
-
Absolute quantitation of myocardial blood flow with (201)Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling.Eur J Nucl Med Mol Imaging. 2008 May;35(5):896-905. doi: 10.1007/s00259-007-0654-4. Epub 2008 Jan 15. Eur J Nucl Med Mol Imaging. 2008. PMID: 18202845
-
A Simple Non-invasive I-123-IMP Autoradiography Method Developed by Modifying the Simple Non-invasive I-123-IMP Microsphere Method.Asia Ocean J Nucl Med Biol. 2018 Winter;6(1):50-56. doi: 10.22038/aojnmb.2017.9555. Asia Ocean J Nucl Med Biol. 2018. PMID: 29333467 Free PMC article.
-
Neuromonitoring after Pediatric Cardiac Arrest: Cerebral Physiology and Injury Stratification.Neurocrit Care. 2024 Feb;40(1):99-115. doi: 10.1007/s12028-023-01685-6. Epub 2023 Apr 1. Neurocrit Care. 2024. PMID: 37002474 Free PMC article. Review.
-
Non-invasive regional cerebral blood flow quantification in the 123I-IMP autoradiography using artificial neural network.PLoS One. 2023 Mar 8;18(3):e0281958. doi: 10.1371/journal.pone.0281958. eCollection 2023. PLoS One. 2023. PMID: 36888603 Free PMC article.
-
Error analysis of autoradiography method for measurement of cerebral blood flow by 123I-IMP brain SPECT: a comparison study with table look-up method and microsphere model method.Ann Nucl Med. 1995 Nov;9(4):185-190. doi: 10.1007/BF03168399. Ann Nucl Med. 1995. PMID: 8770284
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources