Breath-holding capability of adults. Implications for spiral computed tomography, fast-acquisition magnetic resonance imaging, and angiography
- PMID: 7995705
Breath-holding capability of adults. Implications for spiral computed tomography, fast-acquisition magnetic resonance imaging, and angiography
Abstract
Purpose: The breath-holding capabilities of various groups of individuals were evaluated to develop protocols so that patients undergoing spiral computed tomography (CT), digital angiography, and breath-hold magnetic resonance imaging (MRI) can be studied successfully.
Methods: Twenty-five outpatients and 25 inpatients (all adults) were studied before undergoing body CT. Each subject was asked to hold his or her breath for as long as possible. Then each patient was asked to perform as many repetitive 12-second breath holds as possible. These data were correlated with demographic and historical information.
Results: The maximum breath-hold time for inpatients and those outpatients who were heavy smokers or had chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF) was 18 to 32 seconds (95% confidence interval) with a mean of 25 seconds. For all other outpatients, breath-hold time was 38 to 56 seconds (mean = 45 seconds). The 95% confidence interval for the number of 12-second breath holds for these two groups was 4 to 6 breath holds (mean = 4.9) and 6 to 7 breath holds (mean = 6.6), respectively. One inpatient could not hold his breath at all and three others were only able to hold their breath once for short periods. The sex and age of the patient had no significant effect on breath-holding performance.
Conclusions: Breath-holding protocols must account for the diminished capabilities of most inpatients, and outpatients who are heavy smokers or have COPD or CHF. Most outpatients who are not heavy smokers or without COPD or CHF can achieve a single breath hold of 38 seconds, or up to six 12-second breath holds.
Similar articles
-
Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use.Radiology. 2006 Apr;239(1):71-8. doi: 10.1148/radiol.2383042019. Epub 2006 Feb 21. Radiology. 2006. PMID: 16493014
-
Single 20-second acquisition of deep-inspiration breath-hold PET/CT: clinical feasibility for lung cancer.J Nucl Med. 2009 Oct;50(10):1579-84. doi: 10.2967/jnumed.109.064246. Epub 2009 Sep 16. J Nucl Med. 2009. PMID: 19759111 Clinical Trial.
-
A hybrid breath hold and continued respiration-triggered technique for time-resolved 3D MRI perfusion studies in lung cancer.Rofo. 2010 Jan;182(1):45-52. doi: 10.1055/s-0028-1109713. Epub 2009 Oct 26. Rofo. 2010. PMID: 19859857
-
Detection of coronary artery stenoses using breath-hold magnetic resonance coronary angiography. Comparison with conventional x-ray angiography.Eur Rev Med Pharmacol Sci. 2004 May-Jun;8(3):121-8. Eur Rev Med Pharmacol Sci. 2004. PMID: 15368796
-
Imaging of lung ventilation and respiratory dynamics in a single ventilation cycle using hyperpolarized He-3 MRI.J Magn Reson Imaging. 2007 Sep;26(3):630-6. doi: 10.1002/jmri.20965. J Magn Reson Imaging. 2007. PMID: 17685417
Cited by
-
3D late gadolinium enhancement in a single prolonged breath-hold using supplemental oxygenation and hyperventilation.Magn Reson Med. 2014 Sep;72(3):850-7. doi: 10.1002/mrm.24969. Epub 2013 Oct 15. Magn Reson Med. 2014. PMID: 24186772 Free PMC article.
-
Changes in Magnetic Resonance Signal Fluctuation in Superior Sagittal Sinus: Deterioration of Arteriolar Vasomotor Function of Young Smokers.Tomography. 2022 Mar 2;8(2):657-666. doi: 10.3390/tomography8020055. Tomography. 2022. PMID: 35314632 Free PMC article.
-
Dynamic MRI Using SmooThness Regularization on Manifolds (SToRM).IEEE Trans Med Imaging. 2016 Apr;35(4):1106-15. doi: 10.1109/TMI.2015.2509245. Epub 2015 Dec 17. IEEE Trans Med Imaging. 2016. PMID: 26685228 Free PMC article.
-
Dynamic MRI using model-based deep learning and SToRM priors: MoDL-SToRM.Magn Reson Med. 2019 Jul;82(1):485-494. doi: 10.1002/mrm.27706. Epub 2019 Mar 12. Magn Reson Med. 2019. PMID: 30860286 Free PMC article.
-
Ultrasound-based sensors to monitor physiological motion.Med Phys. 2021 Jul;48(7):3614-3622. doi: 10.1002/mp.14949. Epub 2021 Jun 7. Med Phys. 2021. PMID: 33999423 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical