Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 Aug;20(7):489-95.
doi: 10.1007/BF01711901.

Hypocortisolaemia and adrenocortical responsiveness at onset of septic shock

Affiliations

Hypocortisolaemia and adrenocortical responsiveness at onset of septic shock

J L Moran et al. Intensive Care Med. 1994 Aug.

Abstract

Objective: To characterise the plasma cortisol profile and adreno-cortial responsiveness (short Synacthen test) of patients in septic shock.

Design: Retrospective assessment using case-notes and ICU charts.

Setting: University teaching hospital ICU.

Patients: 68 septic shock patients with plasma cortisol and/or short Synacthen test measured at ICU-admission or onset of shock post ICU-admission. Patients were identified from a total population of 155 patients who had PCL and/or SST measured over a 4.5 year period.

Intervention: None.

Measurements and results: Patients with septic shock had a plasma cortisol ranging from 210-8900 nmol/l and mortality of 56%. There were 22 (32%) below (low) and 46 (68%) above (high) a 'critical' plasma cortisol of 500 nmol/l. Using stepwise logistic regression, mortality was adequately predicted by and increased with, increasing plasma cortisol and onset of shock remote from ICU-admission. Short Synacthen tests were available in 33 patients: 11 responders (cortisol increment > 200 nmol/l above baseline 30 min after 0.25 mg intravenous Synacthen) and 22 hypo-responders. Mortality in patients was adequately predicted by and increased with a decrease in cortisol increment post-Synacthen. Thirteen patients (plasma cortisol 606 +/- [SD] 297 nmol/l) had complete haemodynamic profiles before inotropic therapy; no relationship was demonstrated between plasma cortisol and circulatory variables. Follow-up revealed no cases of Addison's disease.

Conclusions: In septic shock, 'hypocortisolaemia' is not uncommon and does not predict a high mortality; adrenocortical hypo-responsiveness may be associated with poor outcome.

PubMed Disclaimer

References

    1. Circ Shock. 1987;22(1):11-22 - PubMed
    1. Crit Care Med. 1988 Mar;16(3):296-7 - PubMed
    1. J Lab Clin Med. 1988 May;111(5):584-90 - PubMed
    1. Anaesthesia. 1981 Jan;36(1):16-21 - PubMed
    1. Naunyn Schmiedebergs Arch Pharmacol. 1972;273(1):134-53 - PubMed