CAAS. II: A second generation system for off-line and on-line quantitative coronary angiography
- PMID: 8001105
- DOI: 10.1002/ccd.1810330116
CAAS. II: A second generation system for off-line and on-line quantitative coronary angiography
Abstract
The Cardiovascular Angiography Analysis System (CAAS) has been completely redesigned and transferred to a modern platform. The user-friendly environment together with a number of image processing techniques and tools allow easy and fast analysis of cardiovascular angiographic images. These images are obtained either on-line by means of a frame grabber hooked on the video output of the X-ray equipment or off-line by digitising 35-mm cine film frames. In addition, images can be acquired more directly by means of a network link. Images stored on disk in different formats, including MS-DOS, can also be analysed. Accurate and reliable quantitative analysis of coronary stenoses and assessment of their related functional significance may offer the clinician a tool in a stratification of patients at risk. The semireal-time environment will make it possible for the cardiologist to quickly respond to the results of recanalisation procedures while the patient is still in the catheterisation laboratory. The addition of a video front end makes the system available to all clinically relevant X-ray imaging equipment. A detailed comparison with the former CAAS on the basis of analysis of 40 arterial segments in routinely acquired cineangiograms demonstrated no statistically significant differences between the two analysis systems. Repeated analysis of the same segments yielded inter- and intraobserver variabilities for the obstruction diameter of 0.096 and 0.108 mm, respectively. For the computed reference diameter the values are 0.099 and 0.096 mm, respectively, and for the percentage diameter stenosis 4.67 and 5.37%, respectively.
Similar articles
-
Accuracy and precision of quantitative digital coronary arteriography: observer-, short-, and medium-term variabilities.Cathet Cardiovasc Diagn. 1993 Mar;28(3):187-98. doi: 10.1002/ccd.1810280301. Cathet Cardiovasc Diagn. 1993. PMID: 8439993
-
In vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS).Catheter Cardiovasc Interv. 2009 Apr 1;73(5):620-6. doi: 10.1002/ccd.21872. Catheter Cardiovasc Interv. 2009. PMID: 19309696
-
Digital geometric measurements in comparison to cinefilm analysis of coronary artery dimensions.Cathet Cardiovasc Diagn. 1993 Apr;28(4):283-90. doi: 10.1002/ccd.1810280404. Cathet Cardiovasc Diagn. 1993. PMID: 8462076
-
Quantitative and qualitative coronary angiographic analysis: review of methods, utility, and limitations.Cathet Cardiovasc Diagn. 1992 Feb;25(2):110-31. doi: 10.1002/ccd.1810250207. Cathet Cardiovasc Diagn. 1992. PMID: 1544153 Review.
-
Quantification of coronary arterial stenoses by multidetector CT angiography in comparison with conventional angiography methods, caveats, and implications.JACC Cardiovasc Imaging. 2011 Feb;4(2):191-202. doi: 10.1016/j.jcmg.2010.10.011. JACC Cardiovasc Imaging. 2011. PMID: 21329905 Review.
Cited by
-
The paclitaxel-eluting Coroflex Please stent pilot study (PECOPS I) : the one-year clinical follow-up.Clin Res Cardiol. 2007 Nov;96(11):803-11. doi: 10.1007/s00392-007-0560-6. Epub 2007 Aug 23. Clin Res Cardiol. 2007. PMID: 17701366 Clinical Trial.
-
Coronary angiography: a review of the state of the art and the evolution of angiography in cardio therapeutics.Front Cardiovasc Med. 2024 Nov 25;11:1468888. doi: 10.3389/fcvm.2024.1468888. eCollection 2024. Front Cardiovasc Med. 2024. PMID: 39654943 Free PMC article. Review.
-
A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries.Int J Card Imaging. 1998 Apr;14(2):75-87. doi: 10.1023/a:1005903705300. Int J Card Imaging. 1998. PMID: 9617637
-
Quantitative multi-modality imaging analysis of a fully bioresorbable stent: a head-to-head comparison between QCA, IVUS and OCT.Int J Cardiovasc Imaging. 2012 Mar;28(3):467-78. doi: 10.1007/s10554-011-9829-y. Epub 2011 Feb 26. Int J Cardiovasc Imaging. 2012. PMID: 21359517 Free PMC article.
-
Comparison of QCA systems.Int J Card Imaging. 1997 Aug;13(4):271-80. doi: 10.1023/a:1005768523234. Int J Card Imaging. 1997. PMID: 9306141 Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources