Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 Jul;79(1):58-65.

The effects of halothane and isoflurane on cerebrocortical microcirculation and autoregulation as assessed by laser-Doppler flowmetry

Affiliations
  • PMID: 8010455

The effects of halothane and isoflurane on cerebrocortical microcirculation and autoregulation as assessed by laser-Doppler flowmetry

J G Lee et al. Anesth Analg. 1994 Jul.

Abstract

The effects of volatile anesthetics on red blood cell flow in the cerebral microcirculation have not been compared. We used laser-Doppler flowmetry, which measures red blood cell flow in the microcirculation to compare the effects of differing concentrations of isoflurane and halothane on cerebrocortical microcirculation. Sprague-Dawley rats were anesthetized with pentobarbital (65 mg/kg intraperitoneally). The animals were tracheotomized, paralyzed, and artificially ventilated. In the first protocol laser-Doppler flow (LDF) was recorded at 0.5, 1, 1.5, and 2 minimum alveolar anesthetic concentration (MAC) halothane or isoflurane, with blood pressure controlled by intravenous phenylephrine infusion (0.5-5 micrograms.kg-1.min-1). In the second protocol the effects of 0.5 and 1.5 MAC halothane and isoflurane on LDF changes in response to changes in mean arterial blood pressure (MABP) were compared. MABP was increased by phenylephrine infusion and decreased by hemorrhage. LDF increased with each 0.5 MAC increase in halothane and isoflurane concentration (P < 0.05). LDF was greater at 1.5 and 2 MAC isoflurane than at equi-MAC halothane (P < 0.01). Autoregulation of LDF was present but attenuated at MABP of 60-140 mm Hg at low halothane and isoflurane concentrations. LDF was increased at 1.5 MAC vs 0.5 MAC for both drugs (P < 0.01). The autoregulation coefficients (percent LDF change/mm Hg MABP change) were 0.41 +/- 0.10, 0.42 +/- 0.07, 0.27 +/- 0.04, and 0.20 +/- 0.05 at 0.5 MAC halothane, 0.5 MAC isoflurane, 1.5 MAC halothane, and 1.5 MAC isoflurane, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources