Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 Jun;57(6):1416-22; discussion 1421-2.
doi: 10.1016/0003-4975(94)90094-9.

Improved survival after extended bridge to cardiac transplantation

Affiliations
Clinical Trial

Improved survival after extended bridge to cardiac transplantation

O H Frazier et al. Ann Thorac Surg. 1994 Jun.

Abstract

In the past, left ventricular assist device (LVAD) support was frequently plagued by complications; thus, bridge to transplantation times were kept short. Increasing evidence suggests that extended bridging provides greater benefit due to improved end-organ perfusion and, thus, generally improved physical condition. To assess whether extended bridging translates into improved long-term survival after transplantation, we reviewed our experience with the HeartMate 1000 IP LVAD (Thermo Cardiosystems, Inc, Woburn, MA). Since January 1988, 19 patients (mean age, 45 +/- 9 years) have undergone extended bridging (mean time, 106 +/- 57 days). Their mean weight was 82 +/- 16 kg, and their mean body surface area was 2.0 +/- 0.2 m2. We define "extended" as the length of support necessary for systemic organ recovery after prolonged heart failure. During support, average pump flow indices ranged from 2.3 to 3.3 L.min-1.m-2, and all patients underwent physical rehabilitation. Between the time of LVAD implantation and explantation, the mean serum creatinine value decreased from 1.63 +/- 0.6 to 1.25 +/- 0.6 mg/dL (p = not significant), and the mean serum total bilirubin value decreased from 2.8 +/- 2.0 to 0.63 +/- 0.11 mg/dL (p < 0.05). All but 1 patient improved from New York Heart Association class IV to class I. Device-related complications were minimal. Twelve control patients ("de facto randomized") who did not receive the LVAD also were evaluated: actuarial survival at 1 year was 0% (p < 0.05); 3 (25%) underwent transplantation and died within 2 months; 9 (75%) died before transplantation.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources