Sitting position for neurosurgery: experience with preoperative contrast echocardiography in 301 patients
- PMID: 8012178
- DOI: 10.1097/00008506-199404000-00003
Sitting position for neurosurgery: experience with preoperative contrast echocardiography in 301 patients
Abstract
A persisting foramen ovale (PFO) is the most common cause of paradoxical air embolism. To detect right-to-left shunting, transthoracic contrast echocardiography was performed preoperatively in 301 patients scheduled for neurosurgical procedures in the sitting position. Echocardiography yielded evaluable results in 285 patients (94.7%). In 72 of 285 patients (25.2%), a PFO was diagnosed on the basis of contrast echo signals appearing in the left atrium or ventricle within 5 heart cycles after application of contrast medium via a peripheral vein. If echo signals appeared in the left heart after more than 5 heart cycles, an intrapulmonary right-to-left shunt was considered (11 patients, 3.9%). Venous air embolism (VAE) occurred in 27.4% of 226 patients operated on in the sitting position and in none of the 59 patients operated on in a nonsitting position. We conclude that the sitting position during neurosurgery should be avoided in patients with preoperative evidence of a right-to-left shunt at contrast echocardiography to reduce the risk of paradoxical air embolism (PAE).
Comment in
-
Preoperative echocardiography and the sitting position.J Neurosurg Anesthesiol. 1994 Apr;6(2):71-4. doi: 10.1097/00008506-199404000-00001. J Neurosurg Anesthesiol. 1994. PMID: 8012176 Review. No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical