Biomechanical analysis of the Gamma nail and sliding hip screw
- PMID: 8020229
Biomechanical analysis of the Gamma nail and sliding hip screw
Abstract
Nine pairs of human cadaveric femora were used to study the biomechanical characteristics of the Gamma nail and a standard telescoping screw plate implant (Ambi) to determine whether there were any mechanical advantages of one system over the other. Parameters studied included structural stiffness, strain distribution, and failure modes for intertrochanteric and subtrochanteric fractures. There was no significant difference in structural stiffness for stable intertrochanteric and subtrochanteric fractures. The Gamma Nail composites, however, were stiffer than the Ambi for unstable subtrochanteric fractures. Both implants effectively unloaded the proximal medial cortex. In each instance, failure of the Gamma nail composite occurred through the distal locking screws. The Gamma nail does not appear to offer any distinct biomechanical advantage over the sliding hip screw system in the treatment of stable and unstable intertrochanteric fractures, but it may play a role in the treatment of unstable subtrochanteric fractures.
Similar articles
-
The effect of implant overlap on the mechanical properties of the femur.J Trauma. 2003 May;54(5):930-5. doi: 10.1097/01.TA.0000060999.54287.39. J Trauma. 2003. PMID: 12777906
-
Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.Clin Biomech (Bristol). 2007 Dec;22(10):1112-8. doi: 10.1016/j.clinbiomech.2007.07.016. Epub 2007 Sep 27. Clin Biomech (Bristol). 2007. PMID: 17900766
-
Biomechanical evaluation of the Ender's pins, the Harris nail, and the dynamic hip screw for the unstable intertrochanteric fracture.Clin Orthop Relat Res. 1986 May;(206):109-12. Clin Orthop Relat Res. 1986. PMID: 3708962
-
Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.Acta Orthop Scand Suppl. 2000 Oct;295:1-31. Acta Orthop Scand Suppl. 2000. PMID: 11116961 Review.
-
The prevention of complications with the Gamma Locking Nail.Am J Orthop (Belle Mead NJ). 1996 May;25(5):357-63. Am J Orthop (Belle Mead NJ). 1996. PMID: 8727086 Review.
Cited by
-
[Comparative stability evaluation of dynamic hip screw and gamma-nail osteosyntheses in unstable pertrochanteric femoral osteotomies].Langenbecks Arch Chir. 1997;382(2):100-6. doi: 10.1007/BF02465097. Langenbecks Arch Chir. 1997. PMID: 9198702 German.
-
Risk factor analysis for delayed union after subtrochanteric femur fracture: quality of reduction and valgization are the key to success.BMC Musculoskelet Disord. 2019 Aug 31;20(1):391. doi: 10.1186/s12891-019-2775-x. BMC Musculoskelet Disord. 2019. PMID: 31470831 Free PMC article.
-
Risk factors for intramedullary nail breakage in proximal femoral fractures: a 10-year retrospective review.Ann R Coll Surg Engl. 2017 Feb;99(2):145-150. doi: 10.1308/rcsann.2016.0297. Epub 2016 Sep 23. Ann R Coll Surg Engl. 2017. PMID: 27659368 Free PMC article. Review.
-
Bifocal treatment for peri-articular femoral nonunions: A retrospective case series review.OTA Int. 2019 Apr 20;2(4):e023. doi: 10.1097/OI9.0000000000000023. eCollection 2019 Dec. OTA Int. 2019. PMID: 33937658 Free PMC article.
-
Outcomes of Wedge Wing in the Lag Screw for Unstable Intertrochanteric Fractures in Elderly Patients.Hip Pelvis. 2021 Jun;33(2):71-77. doi: 10.5371/hp.2021.33.2.71. Epub 2021 Jun 4. Hip Pelvis. 2021. PMID: 34141693 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical