Preclinical safety assessment of iomeprol for injection as contrast medium for myelography
- PMID: 8020518
- DOI: 10.1016/0720-048x(94)90093-0
Preclinical safety assessment of iomeprol for injection as contrast medium for myelography
Abstract
A series of pharmaco-toxicological investigations were carried out in animals in order to assess the neurotolerance of iomeprol, a new nonionic iodinated contrast medium. After intrathecal administration iomeprol was completely eliminated from the cerebrospinal fluid, rapidly cleared from the plasma and excreted unchanged through the kidneys. When administrated intrathecally, iomeprol did not significantly alter the behavioural functions or the physiological activities of the brain. Unlike other contrast media, iomeprol was devoid of any epileptogenic activity. The acute neurotoxicity of iomeprol was comparable with that of iopamidol, but less than that of iohexol, iotrolan and iodixanol. Iomeprol was well tolerated in both rats and dogs following weekly intrathecal administrations for four weeks of doses up to three times higher than those foreseen for clinical use. High neurotolerance in animals and favourable physico-chemical characteristics make iomeprol particularly suitable as a contrast medium for both myelography and cerebral ventriculography.
Similar articles
-
Iomeprol: a review of its use as a contrast medium.Drugs. 2000 May;59(5):1169-86. doi: 10.2165/00003495-200059050-00013. Drugs. 2000. PMID: 10852647 Review.
-
Clinical experience with iomeprol in myelography and myelo-CT: clinical pharmacology and double-blind comparisons with iopamidol, iohexol, and iotrolan.Invest Radiol. 2001 Jan;36(1):22-32. doi: 10.1097/00004424-200101000-00004. Invest Radiol. 2001. PMID: 11176258 Clinical Trial.
-
Pharmacodynamic effects of iomeprol for injection in experimental animals.Eur J Radiol. 1994 May;18 Suppl 1:S32-42. doi: 10.1016/0720-048x(94)90092-2. Eur J Radiol. 1994. PMID: 8020517
-
Toxicological safety assessment of iomeprol, a new X-ray contrast agent.Eur J Radiol. 1994 May;18 Suppl 1:S21-31. doi: 10.1016/0720-048x(94)90091-4. Eur J Radiol. 1994. PMID: 8020516
-
Clinical utility and safety profile of iomeprol.Eur J Radiol. 1994 May;18 Suppl 1:S120-4. doi: 10.1016/0720-048x(94)90106-6. Eur J Radiol. 1994. PMID: 8020514 Review.
Cited by
-
Iomeprol: a review of its use as a contrast medium.Drugs. 2000 May;59(5):1169-86. doi: 10.2165/00003495-200059050-00013. Drugs. 2000. PMID: 10852647 Review.
-
Critical Assessment of Myelography Practices: A Call for Rational Guideline Revision.AJNR Am J Neuroradiol. 2018 Dec;39(12):2378-2384. doi: 10.3174/ajnr.A5867. Epub 2018 Nov 1. AJNR Am J Neuroradiol. 2018. PMID: 30385469 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources