[Evaluation of internationally used blood stabilizers for effective erythrocyte substitution]
- PMID: 80369
[Evaluation of internationally used blood stabilizers for effective erythrocyte substitution]
Abstract
Haemotherapy developed in the direction of transfusing pure blood cell preparations, if possible and enlarging the therapy with plasma fraction considerably. Quality losses of haemotherapeutics will already occur when they are prepared. This is mainly due to the conditions of blood collecting, blood stabiliser, duration and storage temperature from the blood collecting to further processing as well as biological variability of the composition of the donor's blood. The amount of substrate available to erythrocytes differs in various blood stabilisers. Deplasmatized erythrocyte concentrates can be used after several weeks of storage, if a high glucose concentration is present in the blood stabiliser. In CPD media the function of erythrocytes, the oxygen supply of the tissue, will remain intact a week longer than in ACD media. This effect will be increased by xylitol and pyruvate as well as by adding bicarbonate simultaneously. In future a primary importance will have to be attached to an improved storage of erythrocytes in the form of resuspended buffy coat-free erythrocyte concentrates.
Similar articles
-
[Erythrocyte concentrates, low in buffy coat: production, preservation and evaluation of its quality].Folia Haematol Int Mag Klin Morphol Blutforsch. 1980;107(1):104-24. Folia Haematol Int Mag Klin Morphol Blutforsch. 1980. PMID: 6157613 German.
-
[Oxygen transport function of erythrocyte concentrates: a comparison of erythrocytes stored in CPDA-1 and PAGGS-sorbit].Beitr Infusionsther. 1988;21:49-52. Beitr Infusionsther. 1988. PMID: 2463013 German. No abstract available.
-
In vivo study of the influence of adenine and guanosine on the erythrocytes of ACD (pH 5.0 and 5.6) preserved blood.Folia Haematol Int Mag Klin Morphol Blutforsch. 1982;109(3):495-9. Folia Haematol Int Mag Klin Morphol Blutforsch. 1982. PMID: 6182070
-
Blood product storage: does age really matter?Semin Cardiothorac Vasc Anesth. 2012 Sep;16(3):160-5. doi: 10.1177/1089253212445488. Epub 2012 May 3. Semin Cardiothorac Vasc Anesth. 2012. PMID: 22556036 Review.
-
[Storage dependent effects on the oxygen tranport capacity of erythrocyte concentrates].Anaesthesist. 2001 Jan;50 Suppl 1:S9-15. doi: 10.1007/s001010170003. Anaesthesist. 2001. PMID: 11271363 Review. German. No abstract available.