Graft replacement of the descending thoracic aorta: results of "open" distal anastomosis
- PMID: 8037522
- DOI: 10.1016/0003-4975(94)91065-0
Graft replacement of the descending thoracic aorta: results of "open" distal anastomosis
Abstract
With the advent of rapid autotransfusion, we began to repair aneurysms of the descending thoracic and thoracoabdominal aorta by using an "open" technique, in which a single cross-clamp is placed proximal to the aneurysm to exsanguinate the lower body. To determine whether open distal anastomosis effectively protects against spinal cord injury, we studied 71 consecutive patients (50 men, 21 women) who underwent this procedure beginning in April 1989. The patients ranged in age from 31 to 83 years (mean, 63.3 years). Most patients were hypertensive (n = 61; 86%) and symptomatic (n = 54; 76%). Most had been diagnosed with medial degeneration (n = 45; 63.4%) or aortic dissection (n = 16; 22.5%). Five patients (7.0%) were admitted with aortic rupture. We replaced the entire descending thoracic aorta in 31 (43.7%), the thoracoabdominal aorta in 21 (29.6%), and a segment of the descending thoracic aorta in 19 (26.7%). The average distal ischemic time was 22.4 minutes (range, 11 to 42 minutes). The amount of blood returned through the autotransfusion device averaged 2,099 mL. Eight patients (11.3%) died within 30 days (multiple organ failure, 3; hemorrhage, 2; coexisting ischemic heart disease, 3). Spinal cord dysfunction occurred in 6 patients (8.5%) (lower extremity paraparesis, 4; paraplegia, 2). Renal insufficiency requiring dialysis occurred in 4 patients (5.6%). We believe that the low incidence of spinal cord injury and renal insufficiency in this series may have resulted from the free draining of the intercostal and lumbar arteries during aortic occlusion, which decreases cerebrospinal fluid and central venous pressures.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms.J Vasc Surg. 1996 Feb;23(2):230-40. doi: 10.1016/s0741-5214(96)70267-7. J Vasc Surg. 1996. PMID: 8637100
-
Outcome of thoracoabdominal aortic aneurysm surgery. Analysis of 27 consecutive cases.Ann Chir Gynaecol. 1995;84(1):18-23. Ann Chir Gynaecol. 1995. PMID: 7645904
-
Spinal cord protection in descending thoracic and thoracoabdominal aortic aneurysm repair.Semin Thorac Cardiovasc Surg. 1998 Jan;10(1):41-4. doi: 10.1016/s1043-0679(98)70016-4. Semin Thorac Cardiovasc Surg. 1998. PMID: 9469777
-
Spinal cord protection for thoracic aortic surgery.Cardiol Clin. 1999 Nov;17(4):807-13, x. doi: 10.1016/s0733-8651(05)70116-8. Cardiol Clin. 1999. PMID: 10589347 Review.
-
[Spinal cord protection in surgery of the descendent thoracic aorta].Cardiologia. 1998 Mar;43(3):253-9. Cardiologia. 1998. PMID: 9611852 Review. Italian. No abstract available.
Cited by
-
Retrograde replacement of the thoracic aorta.Tex Heart Inst J. 1995;22(2):162-5. Tex Heart Inst J. 1995. PMID: 7647599 Free PMC article.
-
Use of selective hypothermia to protect the spinal cord during resection of thoracoabdominal aneurysms.Tex Heart Inst J. 2000;27(1):29-31. Tex Heart Inst J. 2000. PMID: 10830625 Free PMC article.
-
Selective hypothermia in repair of aneurysms of the descending aorta.Tex Heart Inst J. 1999;26(2):103-6. Tex Heart Inst J. 1999. PMID: 10397431 Free PMC article.
-
Proximal clamping levels in abdominal aortic aneurysm surgery.Tex Heart Inst J. 1999;26(4):264-8. Tex Heart Inst J. 1999. PMID: 10653253 Free PMC article.
-
Is clamp and sew still viable for thoracic aortic resection?Ann Surg. 1996 May;223(5):534-40; discussion 540-3. doi: 10.1097/00000658-199605000-00009. Ann Surg. 1996. PMID: 8651744 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous