Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 Aug;76(8):1149-61.
doi: 10.2106/00004623-199408000-00005.

Dynamic external fixation of unstable fractures of the distal part of the radius. A prospective, randomized comparison with static external fixation

Affiliations
Clinical Trial

Dynamic external fixation of unstable fractures of the distal part of the radius. A prospective, randomized comparison with static external fixation

T G Sommerkamp et al. J Bone Joint Surg Am. 1994 Aug.

Abstract

A prospective, randomized study was done to compare the results of dynamic external fixation (the Clyburn device) with those of static external fixation (the AO/ASIF device) in the treatment of fifty unstable fractures of the distal part of the radius. Mobilization of the wrist from neutral to 30 degrees of flexion was begun in the dynamic-fixator group at approximately two weeks, and full motion, allowing 30 degrees of extension, was started at approximately four weeks. The external fixation frames in both groups were kept in place for approximately ten weeks. Mobilization of the wrist in the dynamic-fixator group provided little gain in the mean motion of the wrist at the time of the removal of the fixator or at the one, six, or twelve-month evaluation. The static-fixator group had greater flexion of the wrist and radial deviation at the early and late follow-up examinations, while the dynamic-fixator group demonstrated only greater ulnar deviation one month after the fixator had been removed. Motion of the wrist in the dynamic-fixator group resulted in a statistically significant loss of radial length compared with that in the static-fixator group (four millimeters compared with one millimeter, p < 0.001). Complications were more frequent in the dynamic-fixator group. As evaluated with a modification of the scoring system of Gartland and Werley, 92 percent of the results at one year were excellent or good in the static-fixator group and 76 percent, in the dynamic-fixator group. The results of this study cannot support the concept of early mobilization with a dynamic external fixator for the treatment of unstable fractures of the distal part of the radius.

PubMed Disclaimer

Publication types