Comparative Study
. 1994 Sep:(306):256-63.

Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques

Affiliations
  • PMID: 8070205
Comparative Study

Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques

B Blair et al. Clin Orthop Relat Res. 1994 Sep.

Abstract

A biomechanical cadaver study was performed to compare the stability and ultimate strength of 3 standard fixation techniques used for treatment of basicervical hip fractures. Twenty one pairs of mildly osteoporotic femurs were selected, based on a computed tomography bone density reading of 40-50 Hounsfeld units and a Singh index of III. After initial mechanical characterization of intact femurs, basicervical femoral neck fractures were created, reduced, and then instrumented with random assignment to 1 of 3 methods of fixation: (1) 3 parallel 6.5-mm cannulated cancellous screws; (2) a 135 degrees sliding hip screw with a 4 hole side plate; and (3) a 135 degrees sliding hip screw with a 4 hole side plate and a 6.5-mm cannulated cancellous screw placed proximal and parallel to the sliding screw. Nine pairs were tested to failure in axial loading, 6 pairs in lateral bending, and 6 pairs in torsion. The group instrumented with the multiple cancellous screws had a significantly (p < 0.01) lower ultimate axial load to failure than either sliding hip screw group. However, the multiple screws demonstrated significantly (p < 0.01) less fracture displacement. There were no statistically significant differences in lateral bending or torsional testing behavior between the 3 fixation methods. Use of the sliding hip screw is recommended rather than use of multiple cancellous screws for treatment of basicervical femoral neck fractures. Although a superiorly located cancellous screw may provide rotational control during sliding hip screw insertion, it provides no incremental fixation after the sliding hip screw is placed.