Telemetric monitoring of intracavernous pressure in freely moving rats during copulation
- PMID: 8072118
- DOI: 10.1016/s0022-5347(17)32566-1
Telemetric monitoring of intracavernous pressure in freely moving rats during copulation
Abstract
Changes in intracavernous pressure (ICP) were recorded in freely moving rats by means of a catheter implanted in the corpus cavernosum and connected to a pressure transducer located subcutaneously. Intracavernous pressure changes and copulatory events (mounts, intromissions and ejaculations) were recorded during several overnight testing sessions with 12 rats in the presence of receptive females. Video recordings of sexual behavior in the implanted and nonimplanted rats revealed that the ICP device did not impair copulatory behavior. Comparison between copulatory behavior and ICP changes revealed that ICP profiles could identify the number of intromissions and ejaculations as well as the timing of these events. The results showed that during mounts, intromissions and ejaculations, ICP increases were 36.9 mm. Hg, 62 mm. Hg and 106.3 mm. Hg in 4 rats. The increases in ICP during mounts and intromissions appeared higher in sexually experienced as compared with sexually naive rats. These results demonstrate the reliability of the telemetric measurement of ICP in freely moving rats under natural physiological conditions. The model provides quantitative data for research on the neurophysiology of penile erection and evaluation of oral treatments for impotence.
Similar articles
-
Intracavernous pressure changes during reflexive penile erections in the rat.Physiol Behav. 1995 May;57(5):837-41. doi: 10.1016/0031-9384(94)00309-s. Physiol Behav. 1995. PMID: 7610132
-
Comparisons of apomorphine-induced erection and spontaneous erection in rats by telemetric assessment of intracavernosal pressure.Andrology. 2015 Mar;3(2):309-14. doi: 10.1111/andr.12004. Epub 2015 Feb 5. Andrology. 2015. PMID: 25656097
-
New Methodology for Investigating Ejaculation Dysfunction: Measuring Intraluminal Seminal Vesicle Pressure in Rats with a Telemetric Device.J Sex Med. 2015 Nov;12(11):2134-40. doi: 10.1111/jsm.13025. Epub 2015 Oct 26. J Sex Med. 2015. PMID: 26503914
-
[Intracavernosal pressure measurement technology in the animal model of erectile dysfunction].Zhonghua Nan Ke Xue. 2016 Apr;22(4):352-5. Zhonghua Nan Ke Xue. 2016. PMID: 30088712 Review. Chinese.
-
Telemetric intracavernosal and intraspongiosal pressure monitoring.J Sex Med. 2008 Oct;5(10):2246-52. doi: 10.1111/j.1743-6109.2008.00997.x. J Sex Med. 2008. PMID: 19007400 Review.
Cited by
-
Sex Differences in Sexual Motivation in Humans and Other Mammals: The Role of Conscious and Unconscious Processes.Behav Sci (Basel). 2024 Mar 27;14(4):277. doi: 10.3390/bs14040277. Behav Sci (Basel). 2024. PMID: 38667073 Free PMC article. Review.
-
The elusive concept of sexual motivation: can it be anchored in the nervous system?Front Neurosci. 2023 Nov 17;17:1285810. doi: 10.3389/fnins.2023.1285810. eCollection 2023. Front Neurosci. 2023. PMID: 38046659 Free PMC article. Review.
-
Modeling Human Sexual Motivation in Rodents: Some Caveats.Front Behav Neurosci. 2019 Aug 27;13:187. doi: 10.3389/fnbeh.2019.00187. eCollection 2019. Front Behav Neurosci. 2019. PMID: 31507386 Free PMC article.
-
Intracavernosal Pressure Recording to Evaluate Erectile Function in Rodents.J Vis Exp. 2018 Jun 6;(136):56798. doi: 10.3791/56798. J Vis Exp. 2018. PMID: 29939168 Free PMC article.
-
Radiotelemetric assessment of intracavernosal pressure in apomorphine-induced erection: hypercholesterolemic rats vs normal control.Int J Impot Res. 2014 Mar-Apr;26(2):41-4. doi: 10.1038/ijir.2013.32. Epub 2013 Jul 25. Int J Impot Res. 2014. PMID: 23884032
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources