Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 May;45(5):1425-31.
doi: 10.1038/ki.1994.186.

Adenosine antagonist theophylline prevents the reduction of glomerular filtration rate after contrast media application

Affiliations
Free article
Clinical Trial

Adenosine antagonist theophylline prevents the reduction of glomerular filtration rate after contrast media application

C M Erley et al. Kidney Int. 1994 May.
Free article

Abstract

Radiographic contrast media (CM) can induce renal failure and this may serve as an experimental model of acute renal failure (ARF). One vasoactive factor likely to be involved in ARF is adenosine. In a double-blind, placebo-controlled study we investigated the effect of theophylline (TP), an adenosine receptor antagonist, regarding changes in renal hemodynamics induced by CM. Thirty-nine patients who received 100 ml of a non-ionic low osmolar CM (iopromide) were studied for changes in GFR and RPF by continuous inulin and PAH clearance before and until four hours after CM application. Forty-five minutes before the application of CM, patients were randomized and received either theophylline (5 mg/kg body wt) or the vehicle and placebo (saline) intravenously in a blinded manner. We additionally measured the creatinine clearance on the day before and two days after CM application. Sodium excretion, N-acetyl-beta-glucosaminidase (NAG) excretion, plasma renin activity (PRA) and aldosterone levels were also measured before and after CM application. Theophylline levels were within the therapeutic range in patients of the theophylline group during and four hours after CM application (59.0 +/- 10.6 mumol/liter and 40.1 +/- 10.9 mumol/liter). GFR, measured by inulin clearance significantly declined under CM application in patients without TP application (N = 19; 88 +/- 40 to 75 +/- 32 ml/min/1.72 m2; P < 0.01). In the group of patients receiving theophylline (N = 18) the GFR remained constant (75 +/- 26 vs. 78 +/- 33 ml/min/1.72 m2).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources