Response mechanism of polymer membrane-based potentiometric polyion sensors
- PMID: 8080104
- DOI: 10.1021/ac00086a009
Response mechanism of polymer membrane-based potentiometric polyion sensors
Abstract
The potentiometric response mechanism of a previously reported polymer membrane-based electrode sensitive to the polyanion heparin is established. Based on transport and extraction studies, the heparin response is attributed to a nonequilibrium change in the phase boundary potential at the sample/membrane interface. While true equilibrium polyion response, obtained for low heparin concentrations only after very long equilibration times (> 20 h), yields the expected Nernstian response slope of < 1 mV/decade, the observed large and reproducible EMF response to clinically relevant heparin concentrations (approximately 10(-7) M) during typical measurement periods (2-5 min) is ascribed to a steady-state kinetic process defined by the flux of the polyion both to the surface and into the bulk of the polymer membrane. A model describing this nonequilibrium response is presented. With this model, the uniqueness of the polymer membrane composition (e.g., very low plasticizer content, strictly controlled cationic site concentration, etc.) required to achieve analytically useful heparin response becomes clear. Practical working conditions and limitations of the sensor are discussed. To support the generality of the steady-state model proposed, corresponding EMF response data for a newly developed membrane electrode sensitive to a polycationic protein (protamine) are also presented. It is shown that the protamine-responsive membrane electrode appears to operate via the exact same kinetic mechanism as the heparin sensing system.
Similar articles
-
Rotating electrode potentiometry: lowering the detection limits of nonequilibrium polyion-sensitive membrane electrodes.Anal Chem. 2001 Jan 15;73(2):332-6. doi: 10.1021/ac000756g. Anal Chem. 2001. PMID: 11199986
-
Improving measurement stability and reproducibility of potentiometric sensors for polyions such as heparin.J Pharm Biomed Anal. 1999 Feb;19(1-2):163-73. doi: 10.1016/s0731-7085(98)00185-x. J Pharm Biomed Anal. 1999. PMID: 10698578
-
Potentiometric sensor for heparin polyion: transient behavior and response mechanism.Anal Chem. 2007 Apr 1;79(7):2892-900. doi: 10.1021/ac062060e. Epub 2007 Feb 23. Anal Chem. 2007. PMID: 17315978
-
Polymer membrane-based ion-, gas- and bio-selective potentiometric sensors.Biosens Bioelectron. 1993;8(1):1-38. doi: 10.1016/0956-5663(93)80041-m. Biosens Bioelectron. 1993. PMID: 8499085 Review.
-
Polymer membranes in clinical sensor applications. I. An overview of membrane function.Biomaterials. 1992;13(14):971-8. doi: 10.1016/0142-9612(92)90147-g. Biomaterials. 1992. PMID: 1472593 Review.
Cited by
-
Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometry.Anal Chim Acta. 2007 Jan 30;583(1):190-6. doi: 10.1016/j.aca.2006.09.042. Epub 2006 Sep 29. Anal Chim Acta. 2007. PMID: 17386545 Free PMC article.
-
Polyion selective polymeric membrane-based pulstrode as a detector in flow-injection analysis.Anal Chem. 2014 Apr 15;86(8):4041-6. doi: 10.1021/ac500567g. Epub 2014 Apr 1. Anal Chem. 2014. PMID: 24650129 Free PMC article.
-
Recent improvements to the selectivity of extraction-based optical ion sensors.Chem Commun (Camb). 2022 Mar 31;58(27):4279-4287. doi: 10.1039/d1cc06636f. Chem Commun (Camb). 2022. PMID: 35201251 Free PMC article. Review.
-
Detection of high-charge density polyanion contaminants in biomedical heparin preparations using potentiometric polyanion sensors.Anal Chem. 2008 Dec 15;80(24):9845-7. doi: 10.1021/ac801879t. Anal Chem. 2008. PMID: 19007240 Free PMC article.
-
Revisiting the Response Mechanism of Polymeric Membrane Based Heparin Electrodes.Electroanalysis. 2012 Jan;24(1):53-59. doi: 10.1002/elan.201100423. Epub 2011 Nov 3. Electroanalysis. 2012. PMID: 23293506 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Other Literature Sources