Effect of arterial PCO2 on local HbO2 and relative Hb concentration in the human brain--a study with the Erlangen micro-lightguide spectrophotometer (EMPHO)
- PMID: 8081189
- DOI: 10.1088/0967-3334/15/2/001
Effect of arterial PCO2 on local HbO2 and relative Hb concentration in the human brain--a study with the Erlangen micro-lightguide spectrophotometer (EMPHO)
Abstract
Intraoperative investigations of local intracapillary haemoglobin oxygenation have been performed in 5 patients during neurosurgical interventions using the Erlangen microlightguide spectrophotometer (EMPHO). As the measurements can be performed in a very short period of time (approximately 60 s) the EMPHO enables rapid monitoring of local haemoglobin oxygenation in the brain. All patients received thiopental anaesthesia and were mechanically ventilated. The local measurements were performed during normoventilation (arterial PCO2--PaCO2 37.8 +/- 0.7 mm Hg) and hyperventilation (PaCO2 31 +/- 0.5 mm Hg). Hyperventilation caused a decrease in the mean SO2 from 47.8% to 41.1%. The number of SO2 values < 50% increased from 58% to 77.8%. The possible significance of the low local SO2 values is discussed.
Similar articles
-
[Local oxygen supply to the cerebral cortex during thiopental and propofol anesthesia. First results].Anaesthesist. 1994 Aug;43(8):534-8. doi: 10.1007/s001010050089. Anaesthesist. 1994. PMID: 7978177 Clinical Trial. German.
-
Monitoring of flaps by measurement of intracapillary haemoglobin oxygenation with EMPHO II: experimental and clinical study.Br J Oral Maxillofac Surg. 1996 Dec;34(6):524-9. doi: 10.1016/s0266-4356(96)90250-8. Br J Oral Maxillofac Surg. 1996. PMID: 8971448
-
Spectrometric measurements in the anterior eye vasculature of the albino rabbit--a study with the EMPHO I.Exp Eye Res. 1991 Mar;52(3):301-9. doi: 10.1016/0014-4835(91)90094-u. Exp Eye Res. 1991. PMID: 2015859
-
The Erlangen micro-lightguide spectrophotometer EMPHO I.Phys Med Biol. 1989 Dec;34(12):1883-900. doi: 10.1088/0031-9155/34/12/011. Phys Med Biol. 1989. PMID: 2694193 Review.
-
Estimating Arterial Partial Pressure of Carbon Dioxide in Ventilated Patients: How Valid Are Surrogate Measures?Ann Am Thorac Soc. 2017 Jun;14(6):1005-1014. doi: 10.1513/AnnalsATS.201701-034FR. Ann Am Thorac Soc. 2017. PMID: 28570147 Review.
Cited by
-
A G-Fresnel Optical Device and Image Processing Based Miniature Spectrometer for Mechanoluminescence Sensor Applications.Sensors (Basel). 2019 Aug 12;19(16):3528. doi: 10.3390/s19163528. Sensors (Basel). 2019. PMID: 31409054 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials