A novel saturation transfer contrast method for 3D time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique
- PMID: 8084237
- DOI: 10.1002/mrm.1910320108
A novel saturation transfer contrast method for 3D time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique
Erratum in
- Magn Reson Med 1994 Nov;32(5):671
Abstract
Saturation transfer contrast (STC) techniques have been employed to decrease the signal intensity of observed water by saturating a broad proton component. The STC pulse, generally spatially nonselective, reduces the signal of brain background tissues as well as inflowing blood in 3D time-of-flight (TOF) angiography. We present a novel technique, a slice-selective off-resonance sinc pulse (SORS), which is employed to enhance inflowing blood and to suppress the signal of stationary background tissues. The STC effects of the SORS and other spatially nonselective methods influencing inflowing blood is discussed in detail. Angiograms using the SORS method are also presented to demonstrate improved vessel conspicuity. In addition, the SORS method is applicable to imagers with a whole-body RF transmitter system.
Similar articles
-
Visualization of lenticulostriate arteries at 3T: Optimization of slice-selective off-resonance sinc pulse-prepared TOF-MRA and its comparison with flow-sensitive black-blood MRA.Acad Radiol. 2014 Jun;21(6):812-6. doi: 10.1016/j.acra.2014.03.007. Acad Radiol. 2014. PMID: 24809322
-
Improved time-of-flight MR angiography of the brain with magnetization transfer contrast.Radiology. 1992 Aug;184(2):395-9. doi: 10.1148/radiology.184.2.1620835. Radiology. 1992. PMID: 1620835
-
Intracranial MRA: single volume vs. multiple thin slab 3D time-of-flight acquisition.J Comput Assist Tomogr. 1993 Jan-Feb;17(1):15-21. J Comput Assist Tomogr. 1993. PMID: 8419427
-
[Structural-functional organization of the cerebral circulatory system in birds].Fiziol Zh SSSR Im I M Sechenova. 1989 Nov;75(11):1616-23. Fiziol Zh SSSR Im I M Sechenova. 1989. PMID: 2697602 Review. Russian.
-
Recent advances in magnetic resonance angiography of the brain.Curr Opin Neurol Neurosurg. 1992 Dec;5(6):859-62. Curr Opin Neurol Neurosurg. 1992. PMID: 1467579 Review.
Cited by
-
Z-Spectrum analysis provides proton environment data (ZAPPED): a new two-pool technique for human gray and white matter.PLoS One. 2015 Mar 13;10(3):e0119915. doi: 10.1371/journal.pone.0119915. eCollection 2015. PLoS One. 2015. PMID: 25768108 Free PMC article.
-
Magnetization transfer by simple sequences of rectangular pulses.MAGMA. 1995 Jul;3(2):83-93. doi: 10.1007/BF01709851. MAGMA. 1995. PMID: 7496890
-
Pseudostenosis of the internal carotid artery in 3D time-of-flight MR angiography: effects of a magnetization transfer contrast pulse and metallic material.Eur Radiol. 2003 Oct;13(10):2298-303. doi: 10.1007/s00330-003-1860-5. Epub 2003 Apr 10. Eur Radiol. 2003. PMID: 12687285
-
Extensive pneumatized air cells causing susceptibility artifacts in the petrosus part of the ICA.Clin Neuroradiol. 2017 Mar;27(1):91-96. doi: 10.1007/s00062-015-0392-0. Epub 2015 May 5. Clin Neuroradiol. 2017. PMID: 25939527
-
Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: impact of VERSE and sparse pulses.Magn Reson Med. 2012 Jul;68(1):188-97. doi: 10.1002/mrm.23226. Epub 2011 Dec 2. Magn Reson Med. 2012. PMID: 22139829 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical