[Hygienic evaluation of contact with asbestos-containing dusts at thermoelectric power plants]
- PMID: 8087461
[Hygienic evaluation of contact with asbestos-containing dusts at thermoelectric power plants]
Abstract
Hygienic evaluation of air in heating power stations revealed the contamination caused by putting and removing heat-proof covers and showed that insulating workers are exposed to asbestos in concentrations sufficient to cause asbestos-related diseases including malignancies. All this is supported by roetgenologic signs of exposure to asbestos, which were seen during the primary medical examination of the workers having long length of service. The study showed that the staffers out of deal with asbestos are also exposed to the asbestos-containing dust in concentrations exceeding the MAC. So all personnel of heating power stations could be assigned to the group for asbestos-related diseases development.
Similar articles
-
Occupational exposure to dusts containing asbestos and chronic airways disease.Int J Occup Med Environ Health. 1996;9(2):117-25. Int J Occup Med Environ Health. 1996. PMID: 8803326 Review.
-
[Epidemiologic research on asbestos related disease in ENEL SpA electricity production plant maintenance].G Ital Med Lav Ergon. 2003 Jul-Sep;25(3):396-7. G Ital Med Lav Ergon. 2003. PMID: 14582273 Italian.
-
[The complex evaluation of risk factors at the thermoelectric power stations in Southern Kuzbass].Med Tr Prom Ekol. 2001;(7):22-6. Med Tr Prom Ekol. 2001. PMID: 11530514 Russian.
-
[Prophylactic examinations of workers formerly employed in asbestos processing plants: outcome of the Amiantus project in 2000-2004].Med Pr. 2006;57(2):101-8. Med Pr. 2006. PMID: 16871953 Polish.
-
[Evaluation of occupational exposure to dusts of mixed free crystalline silica and natural respirable mineral fibers].Med Pr. 2002;53(3):219-27. Med Pr. 2002. PMID: 12369504 Review. Polish.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical