Intravascular catheter associated sepsis: a common problem. The Australian Study on Intravascular Catheter Associated Sepsis
- PMID: 8090116
Intravascular catheter associated sepsis: a common problem. The Australian Study on Intravascular Catheter Associated Sepsis
Abstract
Objective: To estimate the number of episodes of intravascular catheter associated sepsis that occur in Australia per year.
Design and setting: Data were collected from 15 Australian hospitals (mainly tertiary referral hospitals). All positive results of blood cultures were followed up and the primary sepsis site identified and recorded. The average study period was 1.2 years.
Results: Eight hundred and nine episodes of systemic sepsis associated with intravascular catheters were identified from 4957 separate episodes of bacteraemia or fungaemia. Of those in which the catheter site was known, there were 491 episodes of sepsis associated with central vein catheters and 233 with peripheral vein catheters. Systemic sepsis with peripheral vein catheters occurred with 0.36 of every 1000 catheters purchased, but with central vein catheters it was 23 episodes per 1000 catheters (relative risk, 64; 95% confidence interval, 54-76). In these hospitals, 8.2 episodes of intravascular catheter associated sepsis occurred annually per 100 beds and 1.5 episodes per 1000 admissions. From these figures, at least 3000 cases of intravascular sepsis may occur per year in Australia.
Conclusions: Intravascular catheter sepsis is common. Central vein catheters cause more sepsis than peripheral vein catheters. With the greater use of catheters this problem is likely to increase.
Similar articles
-
Prospective study of peripheral arterial catheter infection and comparison with concurrently sited central venous catheters.Crit Care Med. 2008 Feb;36(2):397-402. doi: 10.1097/CCM.0b013e318161f74b. Crit Care Med. 2008. PMID: 18216598
-
Antiseptic chamber-containing hub reduces central venous catheter-related infection: a prospective, randomized study.Crit Care Med. 2003 May;31(5):1318-24. doi: 10.1097/01.CCM.0000026327.58305.22. Crit Care Med. 2003. PMID: 12771597 Clinical Trial.
-
Catheter-related bloodstream infection in adult haematology patients: catheter removal practice and outcome.J Hosp Infect. 2004 Aug;57(4):325-31. doi: 10.1016/j.jhin.2004.04.007. J Hosp Infect. 2004. PMID: 15262394
-
Intravascular catheter-associated infections.Schweiz Med Wochenschr. 1997 Mar 15;127(11):444-56. Schweiz Med Wochenschr. 1997. PMID: 9098918 Review.
-
Rates of infection for single-lumen versus multilumen central venous catheters: a meta-analysis.Crit Care Med. 2003 Sep;31(9):2385-90. doi: 10.1097/01.CCM.0000084843.31852.01. Crit Care Med. 2003. PMID: 14501971 Review.
Cited by
-
Incidence and clinical implication of nosocomial infections associated with implantable biomaterials - catheters, ventilator-associated pneumonia, urinary tract infections.GMS Krankenhhyg Interdiszip. 2011;6(1):Doc18. doi: 10.3205/dgkh000175. Epub 2011 Dec 15. GMS Krankenhhyg Interdiszip. 2011. PMID: 22242099 Free PMC article.
-
Improving the safety of peripheral intravenous catheters.BMJ. 2008 Jul 8;337(7662):a630. doi: 10.1136/bmj.a630. BMJ. 2008. PMID: 18614483 Free PMC article.
-
Prevalence and antimicrobial susceptibility pattern of isolated microorganisms from central venous catheters in ICU patients.Adv Biomed Res. 2014 Mar 25;3:102. doi: 10.4103/2277-9175.129379. eCollection 2014. Adv Biomed Res. 2014. PMID: 24800191 Free PMC article.
-
Attributable mortality of central line associated bloodstream infection: systematic review and meta-analysis.Infection. 2015 Feb;43(1):29-36. doi: 10.1007/s15010-014-0689-y. Epub 2014 Oct 21. Infection. 2015. PMID: 25331552
-
Catheter-related bacteremia from femoral and central internal jugular venous access.Eur J Clin Microbiol Infect Dis. 2008 Sep;27(9):867-71. doi: 10.1007/s10096-008-0507-5. Epub 2008 Apr 2. Eur J Clin Microbiol Infect Dis. 2008. PMID: 18386084
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical