Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Oct;25(10):2072-8; discussion 2078-9.
doi: 10.1161/01.str.25.10.2072.

A long-half-life and fibrin-specific form of tissue plasminogen activator in rabbit models of embolic stroke and peripheral bleeding

Affiliations
Comparative Study

A long-half-life and fibrin-specific form of tissue plasminogen activator in rabbit models of embolic stroke and peripheral bleeding

G R Thomas et al. Stroke. 1994 Oct.

Abstract

Background and purpose: We compared the activity of a new long-half-life, fibrin-specific tissue-type plasminogen activator (TPA) variant with that of wild-type TPA in rabbit models of embolic stroke and peripheral bleeding.

Methods: In the embolic stroke model. TPA-induced clot lysis is followed by continuous monitoring of a radiolabeled clot lodged in the middle cerebral artery. Twenty-four hours after embolization and treatment with either thrombolytic agent or excipient, the brains are removed, fixed, and evaluated for cerebral hemorrhage. In a parallel template bleeding time experiment, the effects of equipotent doses of the two TPA molecules were measured.

Results: Infusion of wild-type TPA or bolus administration of the TPA variant resulted in dose-dependent clot lysis. The TPA variant was found to be an order of magnitude more potent than wild-type TPA on a milligram-per-kilogram basis. Unlike wild-type TPA, the variant caused less systemic activation of plasminogen (P < .05) and fewer hemorrhagic transformations in this model (P < .05). The TPA variant did not extend template bleeding times.

Conclusions: These findings show that by combining increased fibrin specificity with decreased plasma clearance, it is possible to produce a thrombolytic agent that is more convenient and more potent than wild-tpe TPA. At the same time the significant reduction in hemorrhagic conversions may be attributable to the conservation of systemic plasminogen seen with this molecule.