Ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension
- PMID: 8093115
- DOI: 10.7326/0003-4819-118-11-199306010-00008
Ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension
Abstract
Objective: To review published evidence on the use of ambulatory and self-measurement devices in the diagnosis and management of hypertension.
Data sources: Computerized literature searches and manual review of bibliographies.
Study selection: Articles documenting original research pertaining to the diagnosis, treatment, or prognosis of hypertension using ambulatory or self-measurement devices.
Results: Studies that have compared office, self-measured, and ambulatory blood pressures have documented substantial, but nonsystematic, differences. Such findings have raised concern over the appropriateness of diagnosing hypertension and initiating drug therapy in individuals with high office blood pressure but comparatively low self-measured or ambulatory blood pressure ("office" or "white coat" hypertension). Evidence from a large number of cross-sectional studies and a single prospective study suggests that blood pressure- related end-organ damage is more closely associated with ambulatory than with office blood pressure. Less evidence supports self-measured blood pressure in this regard, and data are insufficient to compare ambulatory and self-measured blood pressure in terms of cardiovascular disease risk prediction. The estimated resource cost of an ambulatory blood pressure test is approximately $120, whereas charges range from $100 to $450. The annualized resource cost of blood pressure self-measurement is $50 or less. On a national level, the annual direct costs of ambulatory blood pressure monitoring could be as high as $6 billion, if this technique were used routinely to diagnose and monitor hypertensive patients. The extent to which direct costs would be offset by savings from less frequent or more efficient treatment for hypertension cannot be estimated reliably. Several practical and technical issues also detract from the potential usefulness of ambulatory and self-measurement devices. Finally, there is some evidence that office blood pressures measured by well-trained nonphysicians may serve as an alternative to ambulatory and self-measurement techniques in estimating usual blood pressure.
Conclusion: Limited clinical applications of ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension appear to be warranted. Endorsement of these technologies for routine clinical use, however, will require more convincing evidence of their clinical effectiveness.
Comment in
-
A complication of ambulatory blood pressure monitoring.Ann Intern Med. 1994 Sep 15;121(6):468-9. doi: 10.7326/0003-4819-121-6-199409150-00016. Ann Intern Med. 1994. PMID: 8053627 No abstract available.
-
Automated ambulatory blood pressure devices and self-measured blood pressure monitoring devices: their role in the diagnosis and management of hypertension. American College of Physicians.Ann Intern Med. 1993 Jun 1;118(11):889-92. doi: 10.7326/0003-4819-118-11-199306010-00010. Ann Intern Med. 1993. PMID: 8480963 No abstract available.
Similar articles
-
Self-measurement of blood pressure at home in the management of hypertension.Clin Med Res. 2005 Feb;3(1):19-26. doi: 10.3121/cmr.3.1.19. Clin Med Res. 2005. PMID: 15962017 Free PMC article. Review.
-
Strategies for classifying patients based on office, home, and ambulatory blood pressure measurement.Hypertension. 2015 Jun;65(6):1258-65. doi: 10.1161/HYPERTENSIONAHA.114.05038. Epub 2015 Apr 13. Hypertension. 2015. PMID: 25870194
-
Automated ambulatory blood pressure devices and self-measured blood pressure monitoring devices: their role in the diagnosis and management of hypertension. American College of Physicians.Ann Intern Med. 1993 Jun 1;118(11):889-92. doi: 10.7326/0003-4819-118-11-199306010-00010. Ann Intern Med. 1993. PMID: 8480963 No abstract available.
-
Development of diagnostic thresholds for automated self-measurement of blood pressure in adults. First International Consensus Conference on Blood Pressure Self-Measurement.Blood Press Monit. 2000 Apr;5(2):101-9. Blood Press Monit. 2000. PMID: 10828897 Review.
-
Level of blood pressure control in a hypertensive population when measurements are performed outside the clinical setting.Cardiol J. 2009;16(1):57-67. Cardiol J. 2009. PMID: 19130417
Cited by
-
Ambulatory blood pressure monitoring.Curr Hypertens Rep. 2000 Dec;2(6):558-64. doi: 10.1007/s11906-996-0041-8. Curr Hypertens Rep. 2000. PMID: 11062602 Review.
-
Adiposity-independent sympathetic activity in black men.J Appl Physiol (1985). 2010 Jun;108(6):1613-8. doi: 10.1152/japplphysiol.00058.2010. Epub 2010 Mar 18. J Appl Physiol (1985). 2010. PMID: 20299621 Free PMC article.
-
Evidence based treatment of hypertension. Measurement of blood pressure: an evidence based review.BMJ. 2001 Apr 14;322(7291):908-11. doi: 10.1136/bmj.322.7291.908. BMJ. 2001. PMID: 11302909 Free PMC article. Review. No abstract available.
-
[Self-measurement of blood pressure in primary care (I)].Aten Primaria. 2003 May 15;31(8):545-52. doi: 10.1016/S0212-6567(03)70730-6. Aten Primaria. 2003. PMID: 12765595 Free PMC article. Review. Spanish. No abstract available.
-
Relationship between Joint National Committee-VI classification of hypertension and ambulatory blood pressure in patients with hypertension diagnosed by casual blood pressure.Clin Cardiol. 1998 Nov;21(11):801-6. doi: 10.1002/clc.4960211104. Clin Cardiol. 1998. PMID: 9825191 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical