Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993 Oct;4(4):223-7.

Experimental studies of DL-polylactic acid biodegradable plates and screws in rabbits: computed tomography and molecular weight loss

Affiliations
  • PMID: 8110903

Experimental studies of DL-polylactic acid biodegradable plates and screws in rabbits: computed tomography and molecular weight loss

A Tschakaloff et al. J Craniofac Surg. 1993 Oct.

Abstract

A series of studies were designed to assess the potential of biodegradable DL-polylactic acid (DL-PLA) plates and screws for use in craniofacial surgery. We report on computed tomography (CT) scanning for visualization and postoperative follow-up and the short-term degradation sequelae of a biodegradable plate and screw system in an experimental animal model. Fractures of the nasal bones were created in 20 adult New Zealand white rabbits and rigidly fixed bilaterally with 4-hole plates and screws (n = 12), or left unrepaired for control data (n = 8). CT density, molecular weight, loss of plates and screws, and preliminary bone healing were assessed at 1, 2, 4, and 6 weeks postoperatively. Histologically, no differences in bone healing were noted between control and experimental animals at any time. Three-dimensional CT reconstruction of the skull was possible without artifacts, and no significant differences (p > 0.05) were found in specific CT scan density levels across postoperative intervals. However, significant (p < 0.001) molecular weight loss of the biodegradable plates was observed through 6 weeks postoperatively, reaching approximately 50% of the preoperative molecular weight. Molecular weight loss, however, was not detectable with CT density measurements. Results demonstrated that the use of biodegradable DL-PLA plates and screws had no adverse effect on fracture healing in this model and that CT scanning and three-dimensional reconstruction were possible without artifacts, independent of material degradation and molecular weight loss. These results suggest that this DL-PLA biodegradable system may have the potential for use in craniomandibulofacial surgery when short-term rigid fixation is necessary.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources