Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1975 Oct;48(574):777-90.
doi: 10.1259/0007-1285-48-574-777.

The potential of californium-252 in radiotherapy. Preclinical measurements in physics and radiobiology

The potential of californium-252 in radiotherapy. Preclinical measurements in physics and radiobiology

E J Hall et al. Br J Radiol. 1975 Oct.

Abstract

Californium-252 is a man-made radionuclide (half-life 2-65 years) which emits a mixture of neutrons and gamma rays. It is used in radiotherapy as an alternative to radium and extends the potential benefits of neutrons to interstitial and intracavitary applications. Gamma rays account for a variable proportion of the dose (30 to 50 per cent), depending on the source filtration and the distance from the source. Dosimetry is complicated by this mixture of neutrons and gamma rays. However, measurements with paired ion-chambers, together with Monte-Carlo calculations, have produced dosimetric data that are adequate for clinical use. Many determinations of the oxygen enhancement ratio (OER) have been reported. At the low dose-rates characteristic of interstitial implants, the OER is about 1-5. This is essentially the figure for fast neutrons alone, since at very low dose-rates the contribution of the gamma rays to the biological effect is negligible. As the dose increases, there is a corresponding rise in the OER because the gamma ray contribution can no longer be ignored. The OER is likely to be about 1-8 if 252Cf is used in intracavity treatments and 2-0 if used in "acute" exposures in devices such as the Cathetron. The relative biological effectivenesss (RBE) varies with dose-rate, and with the biological system used to measure it. Radiobiological experiments indicate that 6,000 rads of radium gamma rays in seven days is equivalent to 890 rads of 252Cf neutrons delivered in approximately the same overall time. This figure was suggested some years ago as an interim guide-line until sufficient clinical experience is accumulated.

PubMed Disclaimer

Similar articles

Publication types

MeSH terms

LinkOut - more resources