Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 Mar 1;23(3):753-8.
doi: 10.1016/0735-1097(94)90764-1.

Juxtacardiac pleural pressure during positive end-expiratory pressure ventilation: an intraoperative study in patients with open pericardium

Affiliations
Free article

Juxtacardiac pleural pressure during positive end-expiratory pressure ventilation: an intraoperative study in patients with open pericardium

O A Smiseth et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: This study was conducted to measure the cardiac constraining effect of the lungs during positive end-expiratory pressure and relate extracardiac pleural pressure (radial stress) to airway pressure, right atrial pressure and left ventricular filling.

Background: During positive end-expiratory pressure ventilation, the extracardiac pressure is elevated, and therefore intracavitary filling pressure does not reflect ventricular preload. Estimates of this pressure might be useful clinically to assess left ventricular preload.

Methods: In eight patients who had undergone coronary or valvular surgery and whose pericardium was left widely open, a flat pleural balloon transducer was placed over the anterolateral left ventricular wall. We recorded pulmonary capillary wedge pressure, right atrial pressure and left ventricular short-axis end-diastolic area by transesophageal echocardiography. Incremental positive end-expiratory pressure was applied.

Results: Extracardiac pleural pressure increased (p < 0.01) from 0.6 +/- 1.8 (+/- SD) to 2.4 +/- 1.8, 5.3 +/- 1.5 and 8.2 +/- 1.5 mm Hg at a positive end-expiratory pressure of 5, 10 and 15 cm H2O, respectively. The slope relating extracardiac pleural pressure to positive end-expiratory pressure (in mm Hg) was 0.70 +/- 0.10, and the intercept was zero. Increasing extracardiac pleural pressure was associated with a progressive increase in pulmonary capillary wedge pressure and a decrease in left ventricular end-diastolic area. Consequently, although pulmonary capillary wedge pressure and left ventricular area changed in opposite directions, the value of pulmonary capillary wedge pressure minus extracardiac pleural pressure correlated positively with left ventricular area (r = 0.95, p < 0.001). Changes in right atrial pressure (Pra) correlated with changes in extracardiac pleural pressure (Ppleural): delta Pra = -0.3 + 0.56. delta Ppleural (r = 0.89, p < 0.001).

Conclusions: In postoperative patients with open pericardium, pulmonary capillary wedge pressure minus extracardiac pleural pressure predicts left ventricular end-diastolic area during positive end-expiratory pressure. Further studies should be done to determine whether the observed relations between airway pressure and extracardiac pleural pressure and between right atrial pressure and extracardiac pleural pressure may give clinically useful estimates of left ventricular preload during positive end-expiratory pressure.