Review of pneumatic reduction of intussusception: evolution not revolution
- PMID: 8120773
- DOI: 10.1016/0022-3468(94)90533-9
Review of pneumatic reduction of intussusception: evolution not revolution
Abstract
Pneumatic insufflation of the colon for reduction of pediatric intussusception has recently been recognized in the United States as an alternative method for the more traditional hydrostatic reduction with contrast material. The experience with pneumatic reduction in China is extensive; more than 14,000 cases have been reported in the English language literature. In this review, the general technique used in China is summarized, and the international experience with air insufflation is included in a comparison of hydrostatic and pneumatic reduction techniques.
Similar articles
-
A simple and safe technique for pneumatic reduction of intussusception.Asian J Surg. 2006 Jul;29(3):170-2. doi: 10.1016/S1015-9584(09)60080-4. Asian J Surg. 2006. PMID: 16877218
-
Pneumatic reduction of ileocolic intussusception in children.Pediatr Radiol. 1988;18(1):3-5. doi: 10.1007/BF02395749. Pediatr Radiol. 1988. PMID: 3340431
-
Pneumatic reduction of intussusception in children at Korle Bu Teaching Hospital: an initial experience.Afr J Paediatr Surg. 2011 May-Aug;8(2):176-81. doi: 10.4103/0189-6725.86057. Afr J Paediatr Surg. 2011. PMID: 22005360
-
Air intussusception reduction: "the winds of change".Pediatr Radiol. 1995;25(2):89-91. doi: 10.1007/BF02010312. Pediatr Radiol. 1995. PMID: 7596671 Review.
-
The crescent sign in pneumatic reduction of intussusception.Abdom Radiol (NY). 2018 Mar;43(3):758-759. doi: 10.1007/s00261-017-1259-4. Abdom Radiol (NY). 2018. PMID: 28712056 Review. No abstract available.
Cited by
-
Therapeutic enema for pediatric ileocolic intussusception: using a balloon catheter improves efficacy.Emerg Radiol. 2013 Oct;20(5):385-91. doi: 10.1007/s10140-013-1138-4. Epub 2013 Jun 9. Emerg Radiol. 2013. PMID: 23748969
-
Intraoperative hydrostatic reduction of intussusception.J Indian Assoc Pediatr Surg. 2008 Jul;13(3):107-8. doi: 10.4103/0971-9261.43807. J Indian Assoc Pediatr Surg. 2008. PMID: 20011485 Free PMC article.
-
Nonavailability of Ultrasound: Try Stethoscope in Pneumatic Reduction.J Indian Assoc Pediatr Surg. 2020 Mar-Apr;25(2):76-79. doi: 10.4103/jiaps.JIAPS_129_18. Epub 2020 Jan 28. J Indian Assoc Pediatr Surg. 2020. PMID: 32139984 Free PMC article.
-
Accuracy of ultrasonography for the diagnosis of intussusception in infants in Vietnam.Pediatr Radiol. 2007 Feb;37(2):195-9. doi: 10.1007/s00247-006-0381-1. Epub 2006 Dec 20. Pediatr Radiol. 2007. PMID: 17180657
-
Factors Associated with Failure of Pneumatic Reduction in Children with Ileocolic Intussusception.Children (Basel). 2021 Feb 12;8(2):136. doi: 10.3390/children8020136. Children (Basel). 2021. PMID: 33673183 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources