Abstract
Background: Although adverse reactions to indocyanine green (ICG) are known to occur, the dye has been used for more than 30 years in tests of cardiac and hepatic function, with a high level of safety. Improved digital video technology has renewed interest in the use of intravenous ICG in ophthalmic imaging. This report describes the authors' experience regarding the safety of ICG for digital angiography and their recommendations for its use in the ophthalmic setting.
Methods: Digital ICG videoangiography was performed in 1226 consecutive patients, and 1923 ICG videoangiography tests were performed. A registry of adverse reactions to ICG was established. Criteria were used to define mild, moderate, and severe adverse reactions, and these data were recorded for every ICG study performed.
Results: There were three (0.15%) mild adverse reactions, four (0.2%) moderate reactions, and one (0.05%) severe adverse reaction. There were no deaths.
Conclusions: This study documents the safety of intravenous ICG for use in ophthalmic videoangiography.
Similar articles
-
Classification of choroidal neovascularization by digital indocyanine green videoangiography.Ophthalmology. 1996 Dec;103(12):2054-60. doi: 10.1016/s0161-6420(96)30388-6. Ophthalmology. 1996. PMID: 9003339
-
Intraoperative control of extracranial-intracranial bypass patency by near-infrared indocyanine green videoangiography.J Neurosurg. 2005 Apr;102(4):692-8. doi: 10.3171/jns.2005.102.4.0692. J Neurosurg. 2005. PMID: 15871512 Clinical Trial.
-
The utility and limitations of intraoperative near-infrared indocyanine green videoangiography in aneurysm surgery.World Neurosurg. 2014 Nov;82(5):e607-13. doi: 10.1016/j.wneu.2014.05.033. Epub 2014 Jun 4. World Neurosurg. 2014. PMID: 24907439
-
[A new approach for studying the retinal and choroidal circulation].Nippon Ganka Gakkai Zasshi. 2004 Dec;108(12):836-61; discussion 862. Nippon Ganka Gakkai Zasshi. 2004. PMID: 15656089 Review. Japanese.
-
Use of microscope-integrated near-infrared indocyanine green videoangiography in the surgical treatment of intramedullary cavernous malformations: report of 8 cases.J Neurosurg Spine. 2013 May;18(5):443-9. doi: 10.3171/2013.1.SPINE12482. Epub 2013 Mar 8. J Neurosurg Spine. 2013. PMID: 23473269 Review.
Cited by
-
Small dome-shaped pigment epithelium detachment in polypoidal choroidal vasculopathy: an under-recognized sign of polypoidal lesions on optical coherence tomography?Eye (Lond). 2022 Apr;36(4):733-741. doi: 10.1038/s41433-020-01390-0. Epub 2021 Apr 8. Eye (Lond). 2022. PMID: 33833415 Free PMC article.
-
Logarithmic intensity and speckle-based motion contrast methods for human retinal vasculature visualization using swept source optical coherence tomography.Biomed Opt Express. 2012 Mar 1;3(3):503-21. doi: 10.1364/BOE.3.000503. Epub 2012 Feb 10. Biomed Opt Express. 2012. PMID: 22435098 Free PMC article.
-
Retinal tolerance to dyes.Br J Ophthalmol. 2005 Sep;89(9):1188-91. doi: 10.1136/bjo.2004.062794. Br J Ophthalmol. 2005. PMID: 16113379 Free PMC article.
-
Surgery on breast cancer in pregnancy.Transl Cancer Res. 2019 Oct;8(Suppl 5):S493-S502. doi: 10.21037/tcr.2019.07.16. Transl Cancer Res. 2019. PMID: 35117127 Free PMC article. Review.
-
Removal of sodium from the solvent reduces retinal pigment epithelium toxicity caused by indocyanine green: implications for macular hole surgery.Br J Ophthalmol. 2004 Apr;88(4):556-9. doi: 10.1136/bjo.2003.018523. Br J Ophthalmol. 2004. PMID: 15031176 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical