Application of artificial neural networks for reduction of false-positive detections in digital chest radiographs

Affiliations

Application of artificial neural networks for reduction of false-positive detections in digital chest radiographs

J S Lin et al. Proc Annu Symp Comput Appl Med Care. 1993.

Abstract

A methodology based on the fuzzy set theory and the convolution neural network (CNN) architecture is proposed to tackle the problem of reducing false-positive rate in automatic lung nodule detection. The CNN which simulates human visual mechanism was trained by a supervised back-propagation algorithm based on fuzzy membership functions. The training and testing database consists of image blocks (each 32 x 32 pixels) of suspected lung nodule areas (nodule candidates) which were generated from our pre-scanning program [1]. A linguistic label was assigned to each nodule candidate of the training set, then the label was converted to a membership value through a pre-defined membership function and used as teaching signal (desired outputs) during the network learning. Before the nodule candidate was fed to the network input, it was pre-processed to reduce the complex background noise and the contrast discrepancy resulted from film development. During the network testing phase, a defuzzification process was applied to decipher the trained network's output triggered by the nodule candidate in the testing set. Finally, a Receiver Operating Characteristic (ROC) analysis was used to evaluate the CNN's performance based on the defuzzified output of the testing database. Preliminary results showed an average Az (the performance index) of 0.84 which is equivalent to 0.80 true-positive detection (sensitivity) with an average 2-3 false-positive detections per chest image.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Radiology. 1984 May;151(2):289-93 - PubMed
    1. Med Phys. 1990 Sep-Oct;17(5):861-5 - PubMed
    1. Med Phys. 1990 Mar-Apr;17(2):234-41 - PubMed
    1. Med Phys. 1988 Mar-Apr;15(2):158-66 - PubMed

LinkOut - more resources