Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1994 Jan-Feb;19(1):2-8.

Subarachnoid morphine and fentanyl for labor analgesia. Efficacy and adverse effects

Affiliations
  • PMID: 8148291
Clinical Trial

Subarachnoid morphine and fentanyl for labor analgesia. Efficacy and adverse effects

L E Caldwell et al. Reg Anesth. 1994 Jan-Feb.

Abstract

Background and objectives: The study was designed to compare analgesic efficacy and associated adverse effects between a group of parturients receiving subarachnoid opioids via the combined spinal-epidural (CSE) technique with a group receiving epidural analgesia alone for labor.

Methods: The authors studied 59 healthy parturients admitted for labor and delivery. Group 1 consisted of 26 consecutive patients who received the CSE technique, initially receiving subarachnoid morphine sulfate 0.25 mg, and fentanyl 25 micrograms, for labor analgesia. If patients requested additional analgesia, epidural analgesia was initiated. Group 2 was comprised of 33 consecutive patients who received conventional epidural analgesia. All patients were monitored for the occurrence and treatment of peripartum nausea and vomiting (N/V), pruritus, postdural puncture headache, and respiratory depression.

Results: Additional analgesia was requested by 20/26 (76%) patients in group 1. Group 1 reported more N/V (50% versus 15%, P = .01) and required more therapy for N/V (31% versus 0%, P < .01) than group 2. Furthermore, group 1 reported having more pruritus (50% versus 3%, P < .01), and required more treatment for pruritus (35% versus 3%, P < .01), than group 2. No patient developed significant respiratory depression. Only one patient in group 1 developed a postdural puncture headache, following unintentional dural puncture with the 18 gauge Tuohy needle.

Conclusions: The combination of subarachnoid morphine 0.25 mg and fentanyl 25 micrograms, when used for labor analgesia as part of the CSE technique, was associated with a higher incidence of clinically significant nausea and vomiting and pruritus, compared to conventional epidural anesthesia. Furthermore, the combination of subarachnoid morphine and fentanyl proved ineffective in providing adequate pain relief for the duration of labor and delivery for the majority of patients. The authors recommend that subarachnoid morphine and fentanyl serve a limited role in the treatment of labor pain.

PubMed Disclaimer

LinkOut - more resources