High-performance liquid chromatographic separation of ondansetron enantiomers in serum using a cellulose-derivatized stationary phase and solid-phase extraction
- PMID: 8150880
- DOI: 10.1016/0378-4347(93)80280-h
High-performance liquid chromatographic separation of ondansetron enantiomers in serum using a cellulose-derivatized stationary phase and solid-phase extraction
Abstract
R(-)-Ondansetron and S(+)-ondansetron in human serum were resolved and quantified using a stereospecific HPLC method. Each enantiomer and the internal standard prazosin were isolated from serum using a solid-phase extraction procedure on a cyanopropyl column. Recoveries of 97, 96 and 88% were obtained for the R(-)-enantiomer, the S(+)-enantiomer, and the internal standard, respectively. A cellulose-based chiral analytical column (Chiralcel OD) was used with a mobile phase consisting of hexane-95% ethanol-2-propanol-acetonitrile (65:25:10:1, v/v). Linear calibration curves were obtained for each enantiomer in serum in the concentration range 10-200 ng/ml. The limit of quantitation of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using UV detection at 216 nm was 2.5 ng/ml (signal-to-noise ratio of 3).
Similar articles
-
High-performance liquid chromatographic analysis of ondansetron enantiomers in human serum using a reversed-phase cellulose-based chiral stationary phase and solid-phase extraction.J Chromatogr B Biomed Sci Appl. 1997 Jun 20;694(1):179-84. doi: 10.1016/s0378-4347(97)00112-6. J Chromatogr B Biomed Sci Appl. 1997. PMID: 9234861
-
Liquid chromatographic separation of praziquantel enantiomers in serum using a cellulose-based chiral stationary phase.J Pharm Biomed Anal. 1993 Nov-Dec;11(11-12):1141-4. doi: 10.1016/0731-7085(93)80095-i. J Pharm Biomed Anal. 1993. PMID: 8123726
-
Stereoselective determination of apomorphine enantiomers in serum with a cellulose-based high-performance liquid chromatographic chiral column using solid-phase extraction and ultraviolet detection.J Chromatogr B Biomed Appl. 1996 Nov 15;686(2):297-300. doi: 10.1016/s0378-4347(96)00235-6. J Chromatogr B Biomed Appl. 1996. PMID: 8971613
-
Quantitation of trimipramine enantiomers in human serum by enantioselective high-performance liquid chromatography and mixed-mode disc solid-phase extraction.J Chromatogr B Biomed Sci Appl. 1997 Oct 24;700(1-2):175-82. doi: 10.1016/s0378-4347(97)00324-1. J Chromatogr B Biomed Sci Appl. 1997. PMID: 9390727
-
[Chromatographic enantiomer separation. The phenomenon of chirality].Pharm Unserer Zeit. 1989 Sep;18(5):140-5. doi: 10.1002/pauz.19890180504. Pharm Unserer Zeit. 1989. PMID: 2690147 Review. German. No abstract available.
Cited by
-
Ondansetron clinical pharmacokinetics.Clin Pharmacokinet. 1995 Aug;29(2):95-109. doi: 10.2165/00003088-199529020-00004. Clin Pharmacokinet. 1995. PMID: 7586904 Review.