Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 Apr;35(4):664-71.

Technetium-99m-tetrofosmin to assess myocardial blood flow: experimental validation in an intact canine model of ischemia

Affiliations
  • PMID: 8151391
Free article

Technetium-99m-tetrofosmin to assess myocardial blood flow: experimental validation in an intact canine model of ischemia

A J Sinusas et al. J Nucl Med. 1994 Apr.
Free article

Abstract

Technetium-99m-tetrofosmin is a 99mTc-labeled perfusion tracer demonstrating promise for myocardial perfusion imaging. To determine if 99mTc-tetrofosmin tracks myocardial flow over a pathophysiologic range, the initial myocardial uptake and clearance of 99mTc-tetrofosmin relative to microsphere flow were evaluated in a canine model of ischemia during pharmacological vasodilatation.

Methods: Six open-chest dogs were subjected to complete left anterior descending coronary artery occlusion. Dogs were injected with 99mTc-tetrofosmin and radiolabeled microspheres during pharmacological stress. Coincident with radiotracer injection, dynamic planar imaging and arterial sampling were performed to assess 99mTc-tetrofosmin clearance from blood, myocardium, lung and liver. Fifteen minutes after injection, hearts were excised for well counting of myocardial 99mTc-tetrofosmin activity and flow.

Results: Myocardial 99mTc-tetrofosmin activity correlated linearly with microsphere flow (r = 0.84). Relative 99mTc-tetrofosmin activity underestimated flow at higher flow ranges (> 2.0 ml/min/g) and overestimated flow in low flow ranges (< 0.2 ml/min/g). Technetium-99m-tetrofosmin cleared rapidly from the blood and was retained in the myocardium. Resting target-to-background activity ratios (heart:lung = 3.57 +/- 1.01; heart:liver = 0.58 +/- 0.04) were acceptable 10 min after injection.

Conclusion: Our experimental data support both the validity of 99mTc-tetrofosmin as a myocardial perfusion tracer and the use of early poststress 99mTc-tetrofosmin imaging for the assessment of myocardial perfusion in man.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources