Stereotactic fine needle aspiration of mammographic lesions
- PMID: 8156118
Stereotactic fine needle aspiration of mammographic lesions
Abstract
Stereotactic fine needle aspiration biopsy (FNAB) is being offered at many centers across the United States in lieu of open surgical biopsy for nonpalpable mammographic lesions. To determine how accurate this procedure is in a community hospital, the authors performed stereotactic FNAB of 62 nonpalpable mammographic lesions using Siemens upright stereotactic equipment. FNAB was immediately followed by hook wire localization and open biopsy. Ten lesions were histologically malignant. Seven of these had been identified cytologically as atypical, suspicious or malignant. Three carcinomas were undetected by FNAB, for a sensitivity rate of 70 percent. There were no false-positive FNAB diagnoses. Three different radiologists performed the FNAB and localizations. Our results were insufficiently sensitive to be able to offer stereotactic FNAB to patients in lieu of open surgical biopsy. We are currently planning to evaluate the dedicated stereotactic prone biopsy equipment to compare the results of needle core biopsies with subsequent hook wire localization and open biopsy.
Similar articles
-
Needle localization and fine-needle aspiration biopsy of nonpalpable breast lesions with use of standard and stereotactic equipment.Radiology. 1989 Oct;173(1):53-6. doi: 10.1148/radiology.173.1.2675189. Radiology. 1989. PMID: 2675189
-
Stereotactic core needle biopsy of nonpalpable breast lesions using a conventional mammography unit with an add-on device.AJR Am J Roentgenol. 2003 Aug;181(2):527-31. doi: 10.2214/ajr.181.2.1810527. AJR Am J Roentgenol. 2003. PMID: 12876040
-
Fine-needle aspiration cytology and core biopsy of nonpalpable breast lesions.Curr Opin Radiol. 1992 Oct;4(5):130-8. Curr Opin Radiol. 1992. PMID: 1524972 Review.
-
Stereotactic core needle breast biopsy is an accurate diagnostic technique to assess nonpalpable mammographic abnormalities.J La State Med Soc. 1996 Apr;148(4):167-70. J La State Med Soc. 1996. PMID: 8935619
-
Interventional breast procedures.Curr Probl Diagn Radiol. 1998 Sep-Oct;27(5):133-84. doi: 10.1016/s0363-0188(98)90010-x. Curr Probl Diagn Radiol. 1998. PMID: 9794095 Review.
Cited by
-
Stereotactic fine-needle aspiration biopsy for the evaluation of nonpalpable breast lesions: report of an experience based on 2,988 cases.Ann Surg Oncol. 1996 Mar;3(2):185-91. doi: 10.1007/BF02305799. Ann Surg Oncol. 1996. PMID: 8646520
Publication types
MeSH terms
LinkOut - more resources