Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 May;149(5):1077-84.
doi: 10.1164/ajrccm.149.5.8173744.

Effects of PEEP on VA/Q mismatching in ventilated patients with chronic airflow obstruction

Affiliations

Effects of PEEP on VA/Q mismatching in ventilated patients with chronic airflow obstruction

A Rossi et al. Am J Respir Crit Care Med. 1994 May.

Abstract

Recent work in patients with acute respiratory failure (ARF) due to exacerbation of chronic airflow obstruction (CAO) suggests that application of low degrees of positive end-expiratory pressure (PEEP) can improve rather than impair respiratory mechanics, because PEEP replaces intrinsic PEEP (PEEPi). However, the impact of PEEP on pulmonary gas exchange has not been fully investigated. We designed this study to examine the effects of PEEP and those of PEEPi on ventilation/perfusion (VA/Q) mismatching in mechanically ventilated patients with CAO. Eight patients were studied under four conditions: (1) during controlled mechanical ventilation with the ventilatory setting established by the attending physicians (PEEPi-100%), according to standard criteria; (2) after application of PEEP amounting to 50% (PEEP-50%), and then (3) to 100% (PEEP-100%) of the original PEEPi; and finally, (4) after reduction of PEEPi to 50% of the initial value (PEEPi-50%), obtained by increasing expiratory time and decreasing respiratory rate and tidal volume. Respiratory mechanics, hemodynamics, respiratory blood gases, and VA/Q distributions were measured during each ventilatory mode. At low values of PEEP (PEEP-50%) no changes in respiratory mechanics nor in hemodynamics were observed, but PaO2 moderately increased (from 103 +/- 25.2 to 112 +/- 29.6 mm Hg) and PaCO2 slightly decreased (from 42 +/- 3.7 to 40 +/- 3.3 mm Hg) essentially because of an increase in the mean VA/Q ratio (first moment) of both flood flow (Q, from 0.65 +/- 0.28 to 0.78 +/- 0.29) and ventilation (V, from 4.02 +/- 1.55 to 4.93 +/- 2.00) distributions (p < 0.05, each).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

LinkOut - more resources