High frequency jet ventilation: intraoperative application in infants
Abstract
The potential advantages of the intraoperative use of high frequency jet ventilation (HFJV) when compared with conventional ventilation (CV) include the maintenance of adequate gas exchange and lung function with a relatively motionless surgical field. To determine the pulmonary response to HFJV ventilation in infants during cardiac surgery, we evaluated lung function in nine infants supported with CV and HFJV during a Blalock-Taussig shunt procedure. Infants were randomized to each mode of ventilation with inspiratory and expiratory pressures and FiO2 held constant. Heart rate, blood pressure, arterial blood gases, pulmonary mechanics (lung compliance and resistance), and functional residual capacity (FRC) were compared after 10 minutes of stabilization of each ventilation mode, with the infants in the thoracotomy position and the surgical field adequately exposed. Pulmonary mechanics were measured using esophageal manometry and pneumotachography, and FRC by helium dilution. There was no difference in vital signs, pulmonary mechanics, FRC, or PaO2 on HFJV ventilation when compared with CV. Arterial PaCO2 was lower with a lower mean airway pressure on HFJV when compared with CV. The surgical team subjectively observed a diminished need for lung manipulation and improved ease of access to the surgical field with HFJV. These results indicate that the use of HFJV during closed-heart cardiac surgical procedures in infants provides similar cardiopulmonary stability and some potentially important clinical benefits when compared with CV.
Similar articles
-
High-frequency jet versus conventional ventilation in infants undergoing Blalock-Taussig shunts.Ann Thorac Surg. 1994 Apr;57(4):846-9. doi: 10.1016/0003-4975(94)90187-2. Ann Thorac Surg. 1994. PMID: 8166529 Clinical Trial.
-
Multicenter controlled clinical trial of high-frequency jet ventilation in preterm infants with uncomplicated respiratory distress syndrome.Pediatrics. 1997 Oct;100(4):593-9. doi: 10.1542/peds.100.4.593. Pediatrics. 1997. PMID: 9310511 Clinical Trial.
-
Predictive value of FRC and respiratory compliance on pulmonary gas exchange induced by high frequency jet ventilation in humans.Br J Anaesth. 1990 Apr;64(4):460-8. doi: 10.1093/bja/64.4.460. Br J Anaesth. 1990. PMID: 2185815
-
Proportional assist ventilation in infants.Clin Perinatol. 2001 Sep;28(3):561-78. doi: 10.1016/s0095-5108(05)70107-x. Clin Perinatol. 2001. PMID: 11570155 Review.
-
[Anesthetic management in laryngotracheal surgery. High-frequency jet ventilation as strategy for ventilation during general anesthesia].Anaesthesist. 2010 Nov;59(11):1051-61; quiz 1062-3. doi: 10.1007/s00101-010-1815-6. Anaesthesist. 2010. PMID: 21060980 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical