Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1994 May 27;57(10):1445-50.

Determination of blood flow to the transplanted kidney. A novel application of phase-contrast, cine magnetic resonance imaging

Affiliations
  • PMID: 8197605

Determination of blood flow to the transplanted kidney. A novel application of phase-contrast, cine magnetic resonance imaging

B D Myers et al. Transplantation. .

Abstract

There is at present no noninvasive method that reliably measures blood flow in the poorly functioning renal allograft. The present study was designed to evaluate phase-contrast cine magnetic resonance imaging (PC-cine-MRI) for this purpose. We recruited for study 18 patients who had received kidney transplants 13-66 months earlier from closely related living donors. As judged by the glomerular filtration rate, which was elevated for a single kidney (76 +/- 4 ml/min 1.73 m2), allograft function was excellent, permitting the assumption of unimpaired renal extraction of paminohippuric acid (PAH). Allograft blood flow was determined consecutively on the same day, first by the standard PAH clearance technique and they by the product of the velocity of protons and renal vein cross-sectional area using PC-cine-MRI. MRI determinations could not be completed because of claustrophobia in two patients and failure to image the terminus of the allograft vein another two. Comparison of blood flow in the remaining 14 subjects revealed the two techniques to be strongly related (r = 0.91, P < 0.001). On the average, the renal blood flow rate was similar by each method; 732 +/- 62 by PAH clearance and 703 +/- 69 ml/min by PC-cine-MRI, but the agreement among individuals between the two methods was only modest, with a 95% confidence interval of agreement from -214 to +254 ml/min. We conclude that PC-cine-MRI provides a fairly accurate and noninvasive method for determining the rate of blood flow in the transplanted kidney. With further refinement it should permit the role of depressed blood flow in a variety of acute and chronic forms of human allograft dysfunction to be elucidated in humans for the first time.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources