Transfer-function analysis of UFCT myocardial time-density curves by time-varying recursive least squares analysis
- PMID: 8200670
- DOI: 10.1109/10.277273
Transfer-function analysis of UFCT myocardial time-density curves by time-varying recursive least squares analysis
Abstract
Techniques which assume linear, time-invariant systems have been used to characterize indicator dilution pairs. As a basis for fully describing the relation between left ventricular (LV) and myocardial (MYC) time-density curves, produced by an intravenous contrast medium as measured by ultrafast CT, the assumption of time invariance was tested using recursive least squares regression and CUSUM, a test for time variability of regression parameters. Using data from anesthetized dogs with concomitant microsphere information, constant and time-varying regression models, MYC(t) = b(t)LV(t-1), were generated from time-density curves of flows from two groups: Group 1 (MBF < 2 ml/min/gm, n = 11) and Group 2 (MBF > 2 ml/min/gm, n = 10). The time-varying regression models had reduced root mean square error: 0.6 +/- 1.1 and 0.5 +/- 0.8 versus 7.3 +/- 3.5 and 4.1 +/- 1.6 for Groups 1 and 2, respectively. Significant time variability (p < 0.05) by CUSUM was found in 9/11 Group 1 models and 7/10 Group 2 models. Myocardial blood volume was estimated as the average value of b(t) over the rising portion of the LV curve. Myocardial blood flow was then calculated as myocardial blood volume divided by coronary transit time, determined from gamma variate fits of the LV and scaled, shifted LV curve, with excellent results over a wide range of flows (r = 0.93, y = 0.92 x + 0.28, range of 0.4 to 6.7 ml/min/gm). These results show that measurements of increased myocardial blood flow are possible with an intravenous contrast media, and that movement of contrast medium from intravascular space to extravascular space occurs during the course of the contrast medium's first pass.
Similar articles
-
Measurement of regional myocardial blood flow in dogs by ultrafast CT.Invest Radiol. 1988 May;23(5):348-53. Invest Radiol. 1988. PMID: 3384614
-
[Myocardial microcirculation in humans--new approaches using MRI].Herz. 2003 Mar;28(2):74-81. doi: 10.1007/s00059-003-2451-6. Herz. 2003. PMID: 12669220 German.
-
On the physical and stochastic representation of an indicator dilution curve as a gamma variate.Physiol Meas. 2008 Mar;29(3):281-94. doi: 10.1088/0967-3334/29/3/001. Epub 2008 Feb 11. Physiol Meas. 2008. PMID: 18367805
-
Usage of the T1 effect of an iron oxide contrast agent in an animal model to quantify myocardial blood flow by MRI.Eur J Radiol. 2007 May;62(2):247-56. doi: 10.1016/j.ejrad.2006.12.002. Epub 2006 Dec 22. Eur J Radiol. 2007. PMID: 17188443
-
A fast computed tomographic imaging method for myocardial perfusion.Am J Card Imaging. 1993 Dec;7(4):301-8. Am J Card Imaging. 1993. PMID: 8130607 Review.
Cited by
-
Measurement of myocardial blood flow by UFCT: towards clinical applicability.Int J Card Imaging. 1991;7(2):89-100. doi: 10.1007/BF01798049. Int J Card Imaging. 1991. PMID: 1795128 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials