Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 1994 May;87(5 Suppl 1):15-23.

Saccharide-based contrast agents. Characteristics and diagnostic potential

[Article in English, Italian]
Affiliations
  • PMID: 8209013
Review

Saccharide-based contrast agents. Characteristics and diagnostic potential

[Article in English, Italian]
R Schürmann et al. Radiol Med. 1994 May.

Abstract

Since about 1980 tiny bubbles of gas ("microbubbles") have been known to be highly effective in ultrasonography because of enhancing backscatter ultrasound. After about 25 years of experimental work, the first industrial US contrast agent was approved by health authorities, the galactose microparticle SH U 454-Echovist, Schering AG, launched on the German market in 1991. Its major limitation is represented by the fact that it does not pass the pulmonary barrier and is confined to right heart abnormalities. Therefore another agent has been developed, the transpulmonary derivative of Echovist the galactose-based agent with the code number SH U 508 A (Levovist) which is in the late phase of clinical development for cardiac B-mode and Doppler blood pool US enhancement. A wide number of application areas can be foreseen for this contrast agent, which has been used for a multicenter trial. More than 1,200 patients were included in a European phase-III multicenter trial aimed at assessing the diagnostic efficacy and safety of SH U 508 A (Levovist). The patients included in the study had diagnostically insufficient Doppler signal intensity at routine Doppler or color Doppler vascular imaging. In more than 95% of the patients Doppler signal enhancement was achieved with at least one dose at the scheduled regimen, even in peripheral vessels. Enhanced Doppler US allowed a diagnosis to be made in many patients who would have otherwise undergone more invasive procedures. The diagnostic confidence, evaluated on a numerical rating scale (0-100) increased from 25.2 +/- 22.8% (prevalue) to 77.7 +/- 22.2% after Levovist (mean value +/- standard deviation, as calculated for a subgroup of 513 patients). Repeated i.v. injections were well tolerated. No specific risk was found for patients in any disease group.

PubMed Disclaimer

MeSH terms