The predictive value of abnormal fetal heart rate patterns in early labour
- PMID: 8216112
- DOI: 10.1111/j.1479-828x.1993.tb02379.x
The predictive value of abnormal fetal heart rate patterns in early labour
Abstract
An abnormal early intrapartum cardiotocogram was found to have a sensitivity of 26.4% and a positive predictive value of 28.3% for the detection of fetal acidaemia at birth and a sensitivity of 27.3% and a positive predictive value of 3.3% for the prediction of 5-minute Apgar scores below 7. The presence of meconium in the liquor amnii improved the predictive properties of the test. Although an abnormal early intrapartum feta heart rate pattern indicated a higher risk group, the majority of patients with abnormal early intrapartum cardiograms had a favourable outcome. A normal pattern does not exclude an adverse outcome.