Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 1993 Oct;30(2):173-8.
doi: 10.1002/ccd.1810300220.

Percutaneous transradial artery approach for coronary stent implantation

Affiliations
Case Reports

Percutaneous transradial artery approach for coronary stent implantation

F Kiemeneij et al. Cathet Cardiovasc Diagn. 1993 Oct.

Erratum in

  • Cathet Cardiovasc Diagn 1993 Dec;30(4):358

Abstract

A new approach for implantation of Palmaz Schatz coronary stents is reported. We describe the technique and rationale of coronary stenting with miniaturized angioplasty equipment via the radial artery. This technique is illustrated in three patients. One patient underwent Palmaz Schatz stent implantation for a saphenous vene coronary bypass graft stenosis, the second patient for a restenosis in the anterior descending coronary artery after atherectomy, and the third patient for a second restenosis after balloon angioplasty in the circumflex coronary artery.

PubMed Disclaimer

Publication types

LinkOut - more resources