Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993;67(3):256-60.
doi: 10.1007/BF00864225.

The influence of air temperature on the EMG/force relationship of the quadriceps

Affiliations

The influence of air temperature on the EMG/force relationship of the quadriceps

D G Bell. Eur J Appl Physiol Occup Physiol. 1993.

Abstract

Surface electromyography (EMG) in the past has been used to estimate the intensity of muscle contraction. These estimates were derived from the EMG/force relationship measured at room temperature. How the surface EMG signal is influenced by varying air temperature as it relates to the EMG/force relationship has yet to be investigated. Thus, this study evaluated the influence of different air temperatures (10, 23 and 40 degrees C) on surface EMG during contractions of the quadriceps muscle. Ten subjects [mean (SD) age 29 (7) years and weight 78.3 (7.8) kg] performed a criterion task of five contractions ranging from 10 to 100% of a maximal voluntary contraction, five times over a 1.5-h period in all conditions. The EMG signals generated from the rectus femoris, and the forces associated with the contractions, were captured on FM tape and subsequently digitized at a sampling rate of 2000 Hz. The relationship between EMG and force was different under the different conditions; EMG was reduced at a given force as temperature increased, and the EMG increased in the 10 degrees C environment over time. The differences that occurred at the various temperatures were believed to be related to fluid distribution in the muscle, muscle conduction velocity and sweating. The data imply that the EMG/force relationship measured using surface electrodes is influenced by ambient temperature.

PubMed Disclaimer

References

    1. J Appl Physiol (1985). 1988 Nov;65(5):2046-50 - PubMed
    1. J Appl Physiol (1985). 1991 May;70(5):1996-2002 - PubMed
    1. Crit Rev Biomed Eng. 1984;11(4):251-79 - PubMed
    1. J Appl Physiol (1985). 1992 Jun;72(6):2336-42 - PubMed
    1. IEEE Trans Biomed Eng. 1979 Jun;26(6):313-25 - PubMed

LinkOut - more resources