Fast and reliable QRS alignment technique for high-frequency analysis of signal-averaged ECG
- PMID: 8231317
- DOI: 10.1007/BF02446662
Fast and reliable QRS alignment technique for high-frequency analysis of signal-averaged ECG
Abstract
The process of QRS alignment as required in signal-averaged ECG can impose serious limitations on the spectral range of the signal output. This effect depends basically on the particular alignment technique being used and on the level and type of noise present in the recorded ECG. In clinical studies where a wide-band (1000 Hz) ECG averager is required, the conventional QRS alignment technique, based on maximum coherence matching (MCM) with a template beat, may not perform consistently well. An alternative QRS alignment technique based on the accurate detection of a single fiducial point (SFP) in the bandpass filtered (3-30 Hz) QRS complex was developed. Using computer simulation methods, a comparative assessment of the frequency bandwidths (3 dB points) offered by both MCM and SFP techniques as a function of noise level (15-100 muRMS) and type (EMG and 50 Hz interference), was carried out. The results of the comparative assessment indicated a better performance by the SFP technique in all cases of noise. Hence, the SFP technique would perform more reliably for high-frequency analysis of a noisy ECG, especially when 50 Hz interference is high. Furthermore, SFP is considerably faster than MCM (about four times) when implemented digitally, and its analogue realisation is feasible. The SFP technique is suitable for late-potential analysis in the signal-averaged ECG.
Similar articles
-
Improved alignment method for noisy high-resolution ECG and Holter records using multiscale cross-correlation.IEEE Trans Biomed Eng. 2003 Mar;50(3):344-53. doi: 10.1109/TBME.2003.808821. IEEE Trans Biomed Eng. 2003. PMID: 12669991
-
A comparison of the noise sensitivity of nine QRS detection algorithms.IEEE Trans Biomed Eng. 1990 Jan;37(1):85-98. doi: 10.1109/10.43620. IEEE Trans Biomed Eng. 1990. PMID: 2303275
-
High-resolution ECG on a standard ECG cart.J Electrocardiol. 1988;21 Suppl:S74-9. doi: 10.1016/0022-0736(88)90062-3. J Electrocardiol. 1988. PMID: 3216180
-
Comparison of time domain and frequency domain variables from the signal-averaged electrocardiogram: a multivariable analysis.J Am Coll Cardiol. 1988 May;11(5):1041-51. doi: 10.1016/s0735-1097(98)90064-x. J Am Coll Cardiol. 1988. PMID: 3281991 Review.
-
[Methods for the detection of ventricular late potentials. High amplification ECG, signal averaging technic, frequency analysis and intracardiac mapping].Herz. 1988 Jun;13(3):147-59. Herz. 1988. PMID: 3042571 Review. German.
Cited by
-
Armband Sensors Location Assessment for Left Arm-ECG Bipolar Leads Waveform Components Discovery Tendencies around the MUAC Line.Sensors (Basel). 2022 Sep 24;22(19):7240. doi: 10.3390/s22197240. Sensors (Basel). 2022. PMID: 36236340 Free PMC article.
-
Robust Arm Impedocardiography Signal Quality Enhancement Using Recursive Signal Averaging and Multi-Stage Wavelet Denoising Methods for Long-Term Cardiac Contractility Monitoring Armbands.Sensors (Basel). 2023 Jun 25;23(13):5892. doi: 10.3390/s23135892. Sensors (Basel). 2023. PMID: 37447749 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Miscellaneous