Present and future status of noninvasive selective deep heating using RF in hyperthermia
- PMID: 8231321
- DOI: 10.1007/BF02446643
Present and future status of noninvasive selective deep heating using RF in hyperthermia
Abstract
To achieve hyperthermia using electromagnetic energy, RF of under 100 MHz is basically suitable for the external heating of the deep portions of the body. For applicators using such RF, the following types are considered: capacitive, inductive, radiative and hybrid. With radiative applicators, the intensity of the EM waves radiated from the applicator decreases with propagation into the material to be heated, but the phased annular array of radiative applicators potentially increases the intensity of the EM energy in the deep portion owing to the interference of the waves. Using this method, the focusing of EM energy depends on the dielectric properties of the material to be heated. With respect to RF heating at a lower frequency than the RF used for the annular phased array, some devices have been said to concentrate EM energy in the deep portions, where the characteristics of 'wave' are not utilised. To this end, some methods using capacitive electrodes, an inductive coil, or a combination of both, are being designed. The results of using such methods have shown that it is possible to supply sufficient EM energy to the muscle layers deep in the material to be heated, without heating the fat layers excessively.
Similar articles
-
Deep-heating characteristics of an RF capacitive heating device.Int J Hyperthermia. 1985 Jan-Mar;1(1):15-28. doi: 10.3109/02656738509029271. Int J Hyperthermia. 1985. PMID: 3915511
-
Contact flexible microstrip applicators (CFMA) in a range from microwaves up to short waves.IEEE Trans Biomed Eng. 2002 Sep;49(9):1015-23. doi: 10.1109/TBME.2002.802053. IEEE Trans Biomed Eng. 2002. PMID: 12214873
-
Capacitive heating of phantom and human tumors with an 8 MHz radiofrequency applicator (Thermotron RF-8).Int J Radiat Oncol Biol Phys. 1986 Mar;12(3):365-72. doi: 10.1016/0360-3016(86)90352-4. Int J Radiat Oncol Biol Phys. 1986. PMID: 3957735
-
Stanford 3D hyperthermia treatment planning system. Technical review and clinical summary.Int J Hyperthermia. 1993 Sep-Oct;9(5):627-43. doi: 10.3109/02656739309032052. Int J Hyperthermia. 1993. PMID: 8245576 Review.
-
Regional (deep) heating, clinical studies in progress.Front Radiat Ther Oncol. 1984;18:108-25. doi: 10.1159/000429206. Front Radiat Ther Oncol. 1984. PMID: 6323272 Review. No abstract available.
Cited by
-
Multi-functional magnetic nanoparticles for magnetic resonance imaging and cancer therapy.Biomaterials. 2011 Mar;32(7):1890-905. doi: 10.1016/j.biomaterials.2010.11.028. Epub 2010 Dec 16. Biomaterials. 2011. PMID: 21167595 Free PMC article.
-
An RF phased array applicator designed for hyperthermia breast cancer treatments.Phys Med Biol. 2006 Jan 7;51(1):1-20. doi: 10.1088/0031-9155/51/1/001. Epub 2005 Dec 15. Phys Med Biol. 2006. PMID: 16357427 Free PMC article.
-
Hyperthermic treatment of DMBA-induced rat mammary cancer using magnetic nanoparticles.Biomagn Res Technol. 2008 Feb 25;6:2. doi: 10.1186/1477-044X-6-2. Biomagn Res Technol. 2008. PMID: 18298831 Free PMC article.
-
Advanced Radio Frequency Applicators for Thermal Magnetic Resonance Theranostics of Brain Tumors.Cancers (Basel). 2023 Apr 14;15(8):2303. doi: 10.3390/cancers15082303. Cancers (Basel). 2023. PMID: 37190232 Free PMC article.
-
B1-based SAR reconstruction using contrast source inversion-electric properties tomography (CSI-EPT).Med Biol Eng Comput. 2017 Feb;55(2):225-233. doi: 10.1007/s11517-016-1497-6. Epub 2016 Apr 23. Med Biol Eng Comput. 2017. PMID: 27108291 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources