Concurrent analysis of intracellular glutathione content and gap junctional intercellular communication
- PMID: 8243203
- DOI: 10.1002/cyto.990140707
Concurrent analysis of intracellular glutathione content and gap junctional intercellular communication
Abstract
The potential for performing dual analysis of intracellular glutathione levels and assessment of gap junctional intercellular communication with thiol-specific fluorescent probes in anchored cells was evaluated. Gap junction-mediated diffusion of monochlorobimane and 5-chloromethylfluorescein diacetate following intracellular loading and conjugation with glutathione was compared with 5-carboxyfluorescein diacetate (which is routinely used in laser cytometry to monitor intercellular communication) by means of fluorescence recovery after photobleaching using a variety of communication-competent and communication-incompetent cells. The rate of diffusion of fluorescence among communication-competent cells was inversely proportional to the size of the fluorescent probe employed. The thiol-specific probes were also employed to monitor depletion and synthesis of glutathione following treatments to inhibit glutathione synthesis or consume glutathione by adduct formation. Analysis of gap junctional intercellular communication following glutathione depletion revealed a direct correlation between glutathione levels and intercellular communication. These studies support the utility of the thiol-specific probes to monitor the respective role of cellular glutathione and intercellular communication in the mechanisms of cellular injury.
Similar articles
-
Kinetic analysis of glutathione in anchored cells with monochlorobimane.Cytometry. 1995 Mar 1;19(3):226-34. doi: 10.1002/cyto.990190306. Cytometry. 1995. PMID: 7736868
-
Low-level lead exposure in cultured astroglia: identification of cellular targets with vital fluorescent probes.Neurotoxicology. 1993 Summer-Fall;14(2-3):267-72. Neurotoxicology. 1993. PMID: 8247400
-
Lactic acid inhibition of gap junctional intercellular communication in in vitro astrocytes as measured by fluorescence recovery after laser photobleaching.Glia. 1988;1(6):371-9. doi: 10.1002/glia.440010604. Glia. 1988. PMID: 2976397
-
[Intra- and intercellular Ca(2+)-signal transduction].Verh K Acad Geneeskd Belg. 2000;62(6):501-63. Verh K Acad Geneeskd Belg. 2000. PMID: 11196579 Review. Dutch.
-
Advantages and limitations of commonly used methods to assay the molecular permeability of gap junctional intercellular communication.Biotechniques. 2008 Jul;45(1):33-52, 56-62. doi: 10.2144/000112810. Biotechniques. 2008. PMID: 18611167 Review.
Cited by
-
Cyclic AMP induces rapid increases in gap junction permeability and changes in the cellular distribution of connexin43.J Membr Biol. 1995 Dec;148(3):243-53. doi: 10.1007/BF00235042. J Membr Biol. 1995. PMID: 8747556
-
Functional Characterization of ABCC Proteins from Trypanosoma cruzi and Their Involvement with Thiol Transport.Front Microbiol. 2018 Feb 14;9:205. doi: 10.3389/fmicb.2018.00205. eCollection 2018. Front Microbiol. 2018. PMID: 29491856 Free PMC article.
-
Correlation between the In Vitro Functionality of Stored Platelets and the Cytosolic Esterase-Induced Fluorescence Intensity with CMFDA.PLoS One. 2015 Sep 21;10(9):e0138509. doi: 10.1371/journal.pone.0138509. eCollection 2015. PLoS One. 2015. PMID: 26390135 Free PMC article.
-
CD81 is dispensable for hepatitis C virus cell-to-cell transmission in hepatoma cells.J Gen Virol. 2009 Jan;90(Pt 1):48-58. doi: 10.1099/vir.0.006700-0. J Gen Virol. 2009. PMID: 19088272 Free PMC article.
-
Ultrathin transparent membranes for cellular barrier and co-culture models.Biofabrication. 2017 Feb 14;9(1):015019. doi: 10.1088/1758-5090/aa5ba7. Biofabrication. 2017. PMID: 28140345 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous