The detection of fat embolism by transoesophageal echocardiography during reamed intramedullary nailing. A study of 24 patients with femoral and tibial fractures
- PMID: 8245083
- DOI: 10.1302/0301-620X.75B6.8245083
The detection of fat embolism by transoesophageal echocardiography during reamed intramedullary nailing. A study of 24 patients with femoral and tibial fractures
Abstract
We performed transoesophageal echocardiography on 24 patients during reamed intramedullary nailing of 17 tibial and seven femoral fractures. In 14 patients there was only minimal evidence of emboli passing through the heart, but in six copious showers of small emboli (< 10 mm maximum dimension) were observed. In four other patients, there were also multiple large emboli (> 10 mm maximum dimension). Three of these patients developed fat embolism syndrome postoperatively and one died. Earlier nailing was associated with smaller quantities of emboli.
Comment in
-
Femoral nailing and pulmonary embolism.J Bone Joint Surg Br. 1994 Jul;76(4):677-8. J Bone Joint Surg Br. 1994. PMID: 8027168 No abstract available.
-
Biological effects of intramedullary reaming.J Bone Joint Surg Br. 1993 Nov;75(6):845-7. doi: 10.1302/0301-620X.75B6.8245068. J Bone Joint Surg Br. 1993. PMID: 8245068 No abstract available.
MeSH terms
LinkOut - more resources
Medical