Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993 Dec;88(6):2618-22.
doi: 10.1161/01.cir.88.6.2618.

Value of the P-wave signal-averaged ECG for predicting atrial fibrillation after cardiac surgery

Affiliations

Value of the P-wave signal-averaged ECG for predicting atrial fibrillation after cardiac surgery

J S Steinberg et al. Circulation. 1993 Dec.

Abstract

Background: Atrial fibrillation (AF) is a commonly encountered arrhythmia in clinical practice, and it occurs frequently after cardiac surgery. The P-wave signal-averaged (SA) ECG noninvasively detects atrial conduction delay. Prior studies have described greater P-wave prolongation in patients with a history of AF, but prospective studies have not been performed.

Methods and results: Consecutive patients undergoing cardiac surgery were enrolled. The P-wave SAECG was recorded before surgery from three orthogonal leads using a sinus P-wave template and a cross-correlation function. The averaged P wave was filtered with a least-squares-fit filter and combined into a vector magnitude, and total P-wave duration was measured. Patients were observed after cardiac surgery for the development of AF. One hundred thirty patients were enrolled, and 33 (25%) developed AF 2.6 +/- 2.0 days after surgery. Patients with AF more often had left ventricular hypertrophy on ECG (P < .05) and had a lower ejection fraction (P < .05). The P-wave duration on the SAECG was significantly longer in the AF patients than in those without AF: 152 +/- 18 versus 139 +/- 17 milliseconds (P < .001). An SAECG P-wave duration > 140 milliseconds predicted AF with sensitivity of 77%, specificity of 55%, positive predictive accuracy of 37%, and negative predictive accuracy of 87%. The likelihood of experiencing AF was increased 3.9-fold if the SAECG P-wave duration was prolonged. P-wave SAECG results were independent of other clinical variables by multivariate analysis.

Conclusions: The P-wave duration recorded with the SAECG is a potent, accurate, and independent predictor of AF after cardiac surgery.