Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1993 Oct;31(10):2648-53.
doi: 10.1128/jcm.31.10.2648-2653.1993.

Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis in endocervical specimens

Affiliations
Comparative Study

Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis in endocervical specimens

C A Bass et al. J Clin Microbiol. 1993 Oct.

Abstract

A clinical evaluation of the Amplicor polymerase chain reaction (PCR) assay for the detection of Chlamydia trachomatis in endocervical swabs (Roche Molecular Systems, Branchburg, N.J.) is described. This new clinical system used one-step sample preparation, amplification with biotinylated cryptic plasmid primer pairs (CP24-CP27), uracil-N-glycosylase (AmpErase), and a microtiter format for amplicon capture and detection. Culture with McCoy cells in duplicate 1-dram (3.697-ml) vials with fluorescent immunostaining was the reference system. Endocervical swab samples from 945 women provided 74 culture-positive specimens, of which PCR detected 71. The initial PCR result was positive for 12 additional specimens. Arbitration of the PCR-positive, culture-negative samples by PCR with major outer membrane protein primers, duplicate culture, elementary body direct fluorescent-antibody staining, and DNA extraction PCR showed that all 12 samples were positive for chlamydia, raising the number of truly positive samples from 74 to 86. After arbitration the true sensitivities of PCR and culture were 96.5 and 86%, respectively (P = 0.02). Specificities for both were 100%. For PCR, the positive and negative predictive values were 100 and 99.7%, respectively. Total test efficiency was 99.7%. A high-test-volume (121 samples) timing study with all items included in the College of American Pathologists work load method indicated that this PCR format took approximately 3 min per sample. Because of the high sensitivity, specificity, and improved ease of handling, we found PCR to be a good alternative to culture for detection of C. trachomatis.

PubMed Disclaimer

References

    1. Ann Intern Med. 1988 May;108(5):710-7 - PubMed
    1. J Clin Microbiol. 1993 May;31(5):1209-12 - PubMed
    1. Br J Obstet Gynaecol. 1988 Sep;95(9):916-9 - PubMed
    1. J Clin Microbiol. 1990 Feb;28(2):370-2 - PubMed
    1. J Clin Microbiol. 1990 Jun;28(6):1254-60 - PubMed

Publication types

LinkOut - more resources