Abstract
Stereotactic radiotherapy using a linear accelerator is usually equated with the technique of delivery using multiple non-coplanar arcs, which achieves a spherical dose distribution. As the majority of intracranial lesions are not spherical, a range of schematized tumour shapes were planned to assess the role of static conformal beams in the treatment of irregular lesions. A sphere and 2 ellipsoids, ranging from 20 to 50 mm maximum diameter located intracranially were planned using 3, 4, and 6 non-coplanar static beams with conformal blocks and were compared with four 120 degree non-coplanar arcs. Comparison of the plans was made by the relative sparing of normal tissue outside the target volume using three-dimensional dose-volume distributions. Non-coplanar arcs spared more normal tissue at low isodoses and achieved the best high dose sparing for spherical targets. For the majority of irregular targets, 3 and 4 static beams spared more tissue at doses > or = 50% and > or = 80% than the arc technique. For all irregular volumes, maximum sparing of normal tissue to isodoses > or = 50% and > or = 80% of the treatment isodose was obtained with 6 static conformal beams. We conclude that irregularly shaped tumours suitable for stereotactic radiotherapy with a linear accelerator are better treated with conformal static non-coplanar beams rather than with the multiple arc technique.
Similar articles
-
A comparison of techniques for stereotactic radiotherapy by linear accelerator based on 3-dimensional dose distributions.Radiother Oncol. 1991 Sep;22(1):29-35. doi: 10.1016/0167-8140(91)90066-p. Radiother Oncol. 1991. PMID: 1947210 Review.
-
Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy.Int J Radiat Oncol Biol Phys. 1995 Dec 1;33(5):1221-8. doi: 10.1016/0360-3016(95)00275-8. Int J Radiat Oncol Biol Phys. 1995. PMID: 7493846
-
Does intensity-modulated stereotactic radiotherapy achieve superior target conformity than conventional stereotactic radiotherapy in different intracranial tumours?Clin Oncol (R Coll Radiol). 2009 Jun;21(5):408-16. doi: 10.1016/j.clon.2009.02.002. Epub 2009 Mar 5. Clin Oncol (R Coll Radiol). 2009. PMID: 19268555
-
Conformal radiation therapy with fixed shaped coplanar or noncoplanar radiation beam bouquets: a possible alternative to radiosurgery.Int J Radiat Oncol Biol Phys. 1995 Dec 1;33(5):1209-19. doi: 10.1016/0360-3016(95)02084-5. Int J Radiat Oncol Biol Phys. 1995. PMID: 7493845
-
Radiosurgery with high energy photon beams: a comparison among techniques.Int J Radiat Oncol Biol Phys. 1989 Mar;16(3):857-65. doi: 10.1016/0360-3016(89)90506-3. Int J Radiat Oncol Biol Phys. 1989. PMID: 2493438 Review.
Cited by
-
Noncoplanar verification: a feasibility study using Philips' Pinnacle3 treatment planning system.J Appl Clin Med Phys. 2015 Nov 8;16(6):84–90. doi: 10.1120/jacmp.v16i6.5492. J Appl Clin Med Phys. 2015. PMID: 26699558 Free PMC article.
-
Quality assurance devices for dynamic conformal radiotherapy.J Appl Clin Med Phys. 2004 Winter;5(1):8-15. doi: 10.1120/jacmp.v5i1.1955. Epub 2004 Jan 1. J Appl Clin Med Phys. 2004. PMID: 15753929 Free PMC article.
-
Many-isocenter optimization for robotic radiotherapy.Phys Med Biol. 2020 Feb 10;65(4):045003. doi: 10.1088/1361-6560/ab63b8. Phys Med Biol. 2020. PMID: 31851958 Free PMC article.
-
An integrated treatment delivery system for CSRS and CSRT and clinical applications.J Appl Clin Med Phys. 2003 Autumn;4(4):261-73. doi: 10.1120/jacmp.v4i4.2496. J Appl Clin Med Phys. 2003. PMID: 14604415 Free PMC article.
-
Efficacy of Stereotactic Conformal Radiotherapy vs Conventional Radiotherapy on Benign and Low-Grade Brain Tumors: A Randomized Clinical Trial.JAMA Oncol. 2017 Oct 1;3(10):1368-1376. doi: 10.1001/jamaoncol.2017.0997. JAMA Oncol. 2017. PMID: 28570730 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials