Plasma endothelin level changes during hemorrhagic shock
- PMID: 8263976
- DOI: 10.1097/00005373-199312000-00003
Plasma endothelin level changes during hemorrhagic shock
Abstract
The purpose of this study was to analyze changes in plasma endothelin-1 levels during hemorrhagic shock. Thirty-two mongrel dogs were divided into four equal groups with group I as the controls and groups II through IV as experimental groups. The dogs in the experimental groups underwent hemorrhagic procedures. The mean blood pressure was kept at the level of 65 mm Hg in group II, 50 mm Hg in group III, and 40 mm Hg in group IV. Blood samples were collected from each dog under the following conditions: (1) after induction of anesthesia, when the animals were hemodynamically stable, before the start of shock; (2) 1 minute after the mean arterial pressure dropped to the level designed for each group (shock 1); (3) 15 minutes after shock 1; (4) 30 minutes after shock 1; (5) 1 hour after shock 1; (6) 2 hours after shock 1; (7) 4 hours after shock 1; and (8) 8 hours after shock 1. Plasma endothelin-1 levels both in arterial and venous blood were analyzed in each dog. The results showed that (1) arterial endothelin-1 concentrations were considerably lower than venous concentrations at the baseline level; (2) after the shock-1 point, plasma endothelin-1 concentrations increased, first markedly and then evenly throughout the oligemic period; (3) elevation of plasma endothelin-1 levels was significantly linearly correlated with the amount of blood loss at the time of 2 hours after shock and thereafter; (4) the arterial/venous ratio of plasma endothelin-1 levels during the oligemic period was higher than that in the control group.(ABSTRACT TRUNCATED AT 250 WORDS)
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources